Design Optimization of the Façade - Integrated Solar Thermal Collector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F16%3A00243305" target="_blank" >RIV/68407700:21220/16:00243305 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21720/16:00243305
Výsledek na webu
<a href="http://stc.fs.cvut.cz/pdf16/6518.pdf?_=1460317230" target="_blank" >http://stc.fs.cvut.cz/pdf16/6518.pdf?_=1460317230</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Design Optimization of the Façade - Integrated Solar Thermal Collector
Popis výsledku v původním jazyce
This paper is concerned with the façade - integrated solar thermal solar collector. Façade - integrated solar thermal collectors outperform building - added solar thermal collectors due to smaller heat losses at the back of the collector. The paper analyzes the behavior of different facade collector designs by means of detailed mathematical model of solar thermal collector, focusing on both the performance and architectural aspects. Different configurations of the façade collectors based on single solar glazing, vacuum glazing and double glazing have been investigated. The results of simulation indicate, that in case of using vacuum glazing with special low-emissivity coating (emissivity 0.30, solar transmittance 0.85) and air gap 10 mm (FC3) is possible to achieve higher heat gains compared to standard façade collector solution (FC1). Moreover, façade collector alternative FC3 is two times thinner than FC1 alternative (16 mm against 34 mm).
Název v anglickém jazyce
Design Optimization of the Façade - Integrated Solar Thermal Collector
Popis výsledku anglicky
This paper is concerned with the façade - integrated solar thermal solar collector. Façade - integrated solar thermal collectors outperform building - added solar thermal collectors due to smaller heat losses at the back of the collector. The paper analyzes the behavior of different facade collector designs by means of detailed mathematical model of solar thermal collector, focusing on both the performance and architectural aspects. Different configurations of the façade collectors based on single solar glazing, vacuum glazing and double glazing have been investigated. The results of simulation indicate, that in case of using vacuum glazing with special low-emissivity coating (emissivity 0.30, solar transmittance 0.85) and air gap 10 mm (FC3) is possible to achieve higher heat gains compared to standard façade collector solution (FC1). Moreover, façade collector alternative FC3 is two times thinner than FC1 alternative (16 mm against 34 mm).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0091" target="_blank" >ED2.1.00/03.0091: Univerzitní centrum energeticky efektivních budov (UCEEB)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Studentská tvůrčí činnost 2016 - sborník konference
ISBN
978-80-01-05929-6
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
České vysoké učení technické v Praze, Fakulta strojní
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
19. 4. 2016
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—