Application of the temperature oscillation method in heat transfer measurements at the wall of an agitated vessel
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F18%3A00322215" target="_blank" >RIV/68407700:21220/18:00322215 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.14311/AP.2018.58.0144" target="_blank" >http://dx.doi.org/10.14311/AP.2018.58.0144</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.14311/AP.2018.58.0144" target="_blank" >10.14311/AP.2018.58.0144</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Application of the temperature oscillation method in heat transfer measurements at the wall of an agitated vessel
Popis výsledku v původním jazyce
The Temperature Oscillation Infra-Red Thermography (TOIRT) was used to measure convective heat transfer coefficients at the inner vertical wall of an agitated and baffled vessel. Two impellers were used: an axial six-blade impeller with pitched blades and the Rushton turbine. The TOIRT method represents an indirect method based on measuring the phase shift between the oscillating heat flux applied to one side of the heat transfer surface and the wall temperature response monitored by a contactless infra-red camera at the same side. On the basis of this phase shift, the TOIRT method can indirectly evaluate the heat transfer coefficient on the other side of the heat transfer surface. Two forms of experimental results are presented in this paper. The first one describes graphical dependencies of the local Nusselt number on the dimensionless distance from the vessel bottom for various Reynolds numbers. The second form describes the mean Nusselt number along the wall as a function of the Reynolds number.
Název v anglickém jazyce
Application of the temperature oscillation method in heat transfer measurements at the wall of an agitated vessel
Popis výsledku anglicky
The Temperature Oscillation Infra-Red Thermography (TOIRT) was used to measure convective heat transfer coefficients at the inner vertical wall of an agitated and baffled vessel. Two impellers were used: an axial six-blade impeller with pitched blades and the Rushton turbine. The TOIRT method represents an indirect method based on measuring the phase shift between the oscillating heat flux applied to one side of the heat transfer surface and the wall temperature response monitored by a contactless infra-red camera at the same side. On the basis of this phase shift, the TOIRT method can indirectly evaluate the heat transfer coefficient on the other side of the heat transfer surface. Two forms of experimental results are presented in this paper. The first one describes graphical dependencies of the local Nusselt number on the dimensionless distance from the vessel bottom for various Reynolds numbers. The second form describes the mean Nusselt number along the wall as a function of the Reynolds number.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA14-18955S" target="_blank" >GA14-18955S: Experimentální a teoretická studie konvektivního přenosu tepla v rotujícím turbulentním impaktním proudu.</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Acta Polytechnica
ISSN
1210-2709
e-ISSN
—
Svazek periodika
52
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
11
Strana od-do
144-154
Kód UT WoS článku
000432027700007
EID výsledku v databázi Scopus
2-s2.0-85055010192