Mechanical Response of the Human Aorta to the Delamination at Different Loading Velocities
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F22%3A00358169" target="_blank" >RIV/68407700:21220/22:00358169 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Mechanical Response of the Human Aorta to the Delamination at Different Loading Velocities
Popis výsledku v původním jazyce
Our study deals with the delamination strength of the human aorta. Rectangular strips of the aorta were obtained from three different locations - ascending thoracic aorta, descending thoracic aorta, and abdominal aorta. Peeling experiments were designed to take into account possible effects of arterial anisotropy and a rate-dependent mechanical response. The peeling was carried out at four different loading rates: 0.1, 1, 10, and 50 mms-1. The experiments carried out with samples received from the ascending thoracic aorta and from the abdominal aorta did not show significant effect of the velocity on the delamination strength. On the other hand, the results suggest that in the thoracic region descending aorta delaminates at significantly higher force when teared at 50 mms-1 in comparison with the delamination conducted at speed of 0.1 mms-1. This result was found for both circumferential and longitudinal orientation of samples.
Název v anglickém jazyce
Mechanical Response of the Human Aorta to the Delamination at Different Loading Velocities
Popis výsledku anglicky
Our study deals with the delamination strength of the human aorta. Rectangular strips of the aorta were obtained from three different locations - ascending thoracic aorta, descending thoracic aorta, and abdominal aorta. Peeling experiments were designed to take into account possible effects of arterial anisotropy and a rate-dependent mechanical response. The peeling was carried out at four different loading rates: 0.1, 1, 10, and 50 mms-1. The experiments carried out with samples received from the ascending thoracic aorta and from the abdominal aorta did not show significant effect of the velocity on the delamination strength. On the other hand, the results suggest that in the thoracic region descending aorta delaminates at significantly higher force when teared at 50 mms-1 in comparison with the delamination conducted at speed of 0.1 mms-1. This result was found for both circumferential and longitudinal orientation of samples.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20302 - Applied mechanics
Návaznosti výsledku
Projekt
<a href="/cs/project/GA20-11186S" target="_blank" >GA20-11186S: Mechanika tepenné delaminace a šíření trhliny</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EAN 2021 59th conference on experimental stress analysis
ISBN
978-80-01-06885-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
182-185
Název nakladatele
katedra mechaniky
Místo vydání
Praha
Místo konání akce
Litomyšl
Datum konání akce
29. 9. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—