Není k dispozici
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F04%3A03098638" target="_blank" >RIV/68407700:21230/04:03098638 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Frequency Spectrum Correction Method for the ADC Testing
Popis výsledku v původním jazyce
The main issue of high resolution ADC testing in the frequency range from hundreds of kHz to several MHz is the spectral purity of a testing signal. Commercial low distortion generators can operate only up to the frequency of one or two hundreds of kHz;generators operating in higher frequency range have generally the spectral purity worse than the one corresponding to the ADC resolution. Some improvements can be brought by filtering of the testing signal. Most of the LC filters for the frequency rangeup to several MHz contain coils with ferromagnetic cores. This causes the rise of higher harmonic components. If those components are known or determined by measurement, they can be subtracted from the frequency spectrum measured by the tested ADC. In the ideal case, only a frequency spectrum corresponding to the ADC non-linearity remains. The measurement system designed for frequency spectrum correction and the first results achieved by applying this method are introduced in the paper.
Název v anglickém jazyce
Frequency Spectrum Correction Method for the ADC Testing
Popis výsledku anglicky
The main issue of high resolution ADC testing in the frequency range from hundreds of kHz to several MHz is the spectral purity of a testing signal. Commercial low distortion generators can operate only up to the frequency of one or two hundreds of kHz;generators operating in higher frequency range have generally the spectral purity worse than the one corresponding to the ADC resolution. Some improvements can be brought by filtering of the testing signal. Most of the LC filters for the frequency rangeup to several MHz contain coils with ferromagnetic cores. This causes the rise of higher harmonic components. If those components are known or determined by measurement, they can be subtracted from the frequency spectrum measured by the tested ADC. In the ideal case, only a frequency spectrum corresponding to the ADC non-linearity remains. The measurement system designed for frequency spectrum correction and the first results achieved by applying this method are introduced in the paper.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IMTC'04 Proceedings of the 21th IEEE Instrumentation and Measurement Technology Conference
ISBN
0-7803-8248-X
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
533-536
Název nakladatele
IEEE Instrumentation and Measurement Society
Místo vydání
Como
Místo konání akce
Como
Datum konání akce
18. 5. 2004
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—