Problems of Partial Discharge Measurement: Propagation of Pulses in Winding and Measuring Circuits Calibration
Popis výsledku v původním jazyce
The charge of the partial discharge passing through the winding was evaluated by integration of current pulse on terminals by means of three different methods. It was found that the attenuation of the partial discharge pulse is significant. It was also confirmed by all three evaluating methods with similar results. The measurement both of the attenuation of pulse and changes of partial discharge charge was realized on different types of winding. It resulted in finding that the attenuation of the partialdischarge charge on different types of winding depends on the winding parameters. In testing the dependence of the output calibration charge on the load capacity it was found that no tested calibrator fulfilled ideal conditions of the independence of the calibrator apparent charge size on the size of the object load capacity.
Název v anglickém jazyce
Problems of Partial Discharge Measurement: Propagation of Pulses in Winding and Measuring Circuits Calibration
Popis výsledku anglicky
The charge of the partial discharge passing through the winding was evaluated by integration of current pulse on terminals by means of three different methods. It was found that the attenuation of the partial discharge pulse is significant. It was also confirmed by all three evaluating methods with similar results. The measurement both of the attenuation of pulse and changes of partial discharge charge was realized on different types of winding. It resulted in finding that the attenuation of the partialdischarge charge on different types of winding depends on the winding parameters. In testing the dependence of the output calibration charge on the load capacity it was found that no tested calibrator fulfilled ideal conditions of the independence of the calibrator apparent charge size on the size of the object load capacity.
Klasifikace
Druh
A - Audiovizuální tvorba
CEP obor
JF - Jaderná energetika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
ISBN
80-8073-305-8
Místo vydání
Košice
Název nakladatele resp. objednatele
—
Verze
—
Identifikační číslo nosiče
neuvedeno