Evaluation Conditions for PD Measurement on Basic Test Ar-rangements
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F12%3A43915139" target="_blank" >RIV/49777513:23220/12:43915139 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation Conditions for PD Measurement on Basic Test Ar-rangements
Popis výsledku v původním jazyce
The partial discharge (PD) behaviour of basic test arrange-ments for corona discharges or other discharge sources seems to be well known from the physical point of view. On the other hand the measurement results and, in the same manner, their identification and interpretation can be differ-ent depending on the measurement or evaluation condi-tions. Therefore some typical PD basic arrangements representing corona discharges like needle-plane, needle-plane with insulating sheet and needle-sphere as well as a gliding discharge set and several prepared generator bars were investigated. The PD measurement was performed with a standardized measuring circuit according to the IEC standard 20670 but under different measurement conditions like frequency range. Additionally, the standardized PD quantities as the apparent charge q, the repetition rate n respectively the phase angle of PD pulses fí related to the test voltage were compared with the results of unconventional method Pulse- Sequence-
Název v anglickém jazyce
Evaluation Conditions for PD Measurement on Basic Test Ar-rangements
Popis výsledku anglicky
The partial discharge (PD) behaviour of basic test arrange-ments for corona discharges or other discharge sources seems to be well known from the physical point of view. On the other hand the measurement results and, in the same manner, their identification and interpretation can be differ-ent depending on the measurement or evaluation condi-tions. Therefore some typical PD basic arrangements representing corona discharges like needle-plane, needle-plane with insulating sheet and needle-sphere as well as a gliding discharge set and several prepared generator bars were investigated. The PD measurement was performed with a standardized measuring circuit according to the IEC standard 20670 but under different measurement conditions like frequency range. Additionally, the standardized PD quantities as the apparent charge q, the repetition rate n respectively the phase angle of PD pulses fí related to the test voltage were compared with the results of unconventional method Pulse- Sequence-
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 13th International Scientific Conference Electric Power Engineering 2012
ISBN
978-80-214-4514-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
827-832
Název nakladatele
Brno University of Technology
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
23. 5. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—