PD Behaviour of Basic Test Arrangements under Different Measurement Conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F12%3A43915801" target="_blank" >RIV/49777513:23220/12:43915801 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
PD Behaviour of Basic Test Arrangements under Different Measurement Conditions
Popis výsledku v původním jazyce
The PD behaviour of so-called basic test arrangements as for corona discharge or other discharge sources seems to be well known from the physical point of view. On the other hand the measurement results and, in the same manner, their identification and interpretation can be different, because this is depending on the measurement or evaluation conditions. Therefore some typical basic arrangements representing corona discharges as needle-plane, needle-plane with insulating sheet and needle -sphere as wellas artificial cavity into insulating material were investigated. In a previous paper the pd behaviour of the corona set- ups in air were already discussed. Additional to that the pd behaviour of typical internal pd source under different measurement condition is described. In this paper the most recognized values are compared at the well defined laboratory set ups as defined. During these investigations the standard evaluation methods according to IEC 60270, PRPD pattern and pulse seque
Název v anglickém jazyce
PD Behaviour of Basic Test Arrangements under Different Measurement Conditions
Popis výsledku anglicky
The PD behaviour of so-called basic test arrangements as for corona discharge or other discharge sources seems to be well known from the physical point of view. On the other hand the measurement results and, in the same manner, their identification and interpretation can be different, because this is depending on the measurement or evaluation conditions. Therefore some typical basic arrangements representing corona discharges as needle-plane, needle-plane with insulating sheet and needle -sphere as wellas artificial cavity into insulating material were investigated. In a previous paper the pd behaviour of the corona set- ups in air were already discussed. Additional to that the pd behaviour of typical internal pd source under different measurement condition is described. In this paper the most recognized values are compared at the well defined laboratory set ups as defined. During these investigations the standard evaluation methods according to IEC 60270, PRPD pattern and pulse seque
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0094" target="_blank" >ED2.1.00/03.0094: Regionální inovační centrum elektrotechniky (RICE)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 2012 IEEE International Conference on Condition Monitoring and Diagnosis
ISBN
978-1-4673-1020-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
557-560
Název nakladatele
IEEE
Místo vydání
Red Hook
Místo konání akce
Bali-Indonesia
Datum konání akce
23. 9. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—