Detekce indukované korové aktivity pomocí spektrální analýzy elektroencefalogramu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F07%3A03131975" target="_blank" >RIV/68407700:21230/07:03131975 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Induced Cortical Activity Detection using Spectral Analysis of Electroencephalogram
Popis výsledku v původním jazyce
Failed-back surgery syndrome (FBSS) develops after unsuccessful discotomy in some patients. It causes a chronic, neuropathic pain of lower back and legs that cannot be effectively suppressed by chemical analgesics. To alleviate the pain, an electric stimulation of the dorsal spinal cord (SCS) can be applied. Its analgesic effects might be connected with induced rhythmical activity that occurs in pain matrix during the stimulation. Hence, we analyzed EEG recordings of ten patients, whose neuropathic painwas reduced using SCS, to find out whether the SCS induced the cortical oscillations at the same frequency. The analysis was performed using power spectral density (PSD). During SCS, statistically significant increase of PSD was found at the stimulationfrequency over the central midline electrodes in eight patients. The results suggest that SCS induces the oscillatory activity in the medial motor and premotor cortical regions, which can be successfully detected by spectral analysis.
Název v anglickém jazyce
Induced Cortical Activity Detection using Spectral Analysis of Electroencephalogram
Popis výsledku anglicky
Failed-back surgery syndrome (FBSS) develops after unsuccessful discotomy in some patients. It causes a chronic, neuropathic pain of lower back and legs that cannot be effectively suppressed by chemical analgesics. To alleviate the pain, an electric stimulation of the dorsal spinal cord (SCS) can be applied. Its analgesic effects might be connected with induced rhythmical activity that occurs in pain matrix during the stimulation. Hence, we analyzed EEG recordings of ten patients, whose neuropathic painwas reduced using SCS, to find out whether the SCS induced the cortical oscillations at the same frequency. The analysis was performed using power spectral density (PSD). During SCS, statistically significant increase of PSD was found at the stimulationfrequency over the central midline electrodes in eight patients. The results suggest that SCS induces the oscillatory activity in the medial motor and premotor cortical regions, which can be successfully detected by spectral analysis.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Applied Electronics 2007
ISBN
978-80-7043-537-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
211-214
Název nakladatele
Západočeská universita
Místo vydání
Plzeň
Místo konání akce
Pilsen
Datum konání akce
5. 9. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—