Applicator for In-vivo Experiments on Mice with Melanoma Tumour
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F08%3A00142528" target="_blank" >RIV/68407700:21230/08:00142528 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Applicator for In-vivo Experiments on Mice with Melanoma Tumour
Popis výsledku v původním jazyce
This paper describes a MW applicator designed to treat mice with small melanoma tumours. The applicator is composed by a planar dielectric structure metallized on both sides. The two metallizations are shorted all around the applicator in order to createa cavity resonator at the frequency 2450 MHz. On one metallization is obtained a slot-line ring aperture with the function to radiate the energy to the biological tissue. An EM field simulator was used to optimize the dimensions of the applicator in order to obtain the most suitable power absorption distribution inside the biological tissue. The simulator was also used to predict the SAR distribution inside an agar phantom with EM characteristics similar to muscles tissue. The results of simulations are supported by temperature measurements made on agar phantom. These results have shown the possibility to use this applicator for in-vivo experiment on mice with small melanoma tumors.
Název v anglickém jazyce
Applicator for In-vivo Experiments on Mice with Melanoma Tumour
Popis výsledku anglicky
This paper describes a MW applicator designed to treat mice with small melanoma tumours. The applicator is composed by a planar dielectric structure metallized on both sides. The two metallizations are shorted all around the applicator in order to createa cavity resonator at the frequency 2450 MHz. On one metallization is obtained a slot-line ring aperture with the function to radiate the energy to the biological tissue. An EM field simulator was used to optimize the dimensions of the applicator in order to obtain the most suitable power absorption distribution inside the biological tissue. The simulator was also used to predict the SAR distribution inside an agar phantom with EM characteristics similar to muscles tissue. The results of simulations are supported by temperature measurements made on agar phantom. These results have shown the possibility to use this applicator for in-vivo experiment on mice with small melanoma tumors.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 14th Conference on Microwave Techniques COMITE 2008
ISBN
978-1-4244-2137-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Československá sekce IEEE
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
23. 4. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—