Ceiling radiant cooling: Comparison of ARMAX and subspace identification modelling methods
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F10%3A00157521" target="_blank" >RIV/68407700:21230/10:00157521 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Ceiling radiant cooling: Comparison of ARMAX and subspace identification modelling methods
Popis výsledku v původním jazyce
The building of the Faculty of Mechanical Engineering, Czech Technical University in Prague - Dejvice, has been heated by a ceiling radiant heating system (''Crittall'' system) since 1961. One building block has been equipped by means which enable the use of the pipes of the radiant heating system for ceiling radiant cooling. As optimization of this system is desired, the first step to be performed is the identification. Because of a complicated physical description of the entire system, and a set of measured data which is large enough to perform statistical identification, a decision was made to identify the system by ARMAX model identification and subspace identification methods. The resulting identified model shows a standard deviation of 0.2-0.3 °Con the verification data. The model identified by the subspace methods, enhanced by a Kalman filter, shows a standard deviation of 0.063 °C for out
Název v anglickém jazyce
Ceiling radiant cooling: Comparison of ARMAX and subspace identification modelling methods
Popis výsledku anglicky
The building of the Faculty of Mechanical Engineering, Czech Technical University in Prague - Dejvice, has been heated by a ceiling radiant heating system (''Crittall'' system) since 1961. One building block has been equipped by means which enable the use of the pipes of the radiant heating system for ceiling radiant cooling. As optimization of this system is desired, the first step to be performed is the identification. Because of a complicated physical description of the entire system, and a set of measured data which is large enough to perform statistical identification, a decision was made to identify the system by ARMAX model identification and subspace identification methods. The resulting identified model shows a standard deviation of 0.2-0.3 °Con the verification data. The model identified by the subspace methods, enhanced by a Kalman filter, shows a standard deviation of 0.063 °C for out
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/2A-1TP1%2F084" target="_blank" >2A-1TP1/084: *Integrace systémů budov, výzkum a aplikace inteligentních algoritmů ovlivňujících spotřeby energií budov a obytných domů.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Building and Environment
ISSN
0360-1323
e-ISSN
—
Svazek periodika
45
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
000271350500026
EID výsledku v databázi Scopus
—