Processing Holter ECG signal corrupted with noise: Using ICA for QRS complex detection
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F10%3A00172055" target="_blank" >RIV/68407700:21230/10:00172055 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/ISABEL.2010.5702896" target="_blank" >http://dx.doi.org/10.1109/ISABEL.2010.5702896</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ISABEL.2010.5702896" target="_blank" >10.1109/ISABEL.2010.5702896</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Processing Holter ECG signal corrupted with noise: Using ICA for QRS complex detection
Popis výsledku v původním jazyce
Holter recording of electrocardiographic signal (ECG) is usually disturbed by noise added to measured useful signal due to e. g. worse contact skin-electrode, body movements, etc. Our general goal is to find at least some piece of informatik from ECG (inour case - positions of QRS complexes) in corrupted signal, on which common preprocessing methods fail. The main purpose of the article is description of an automatic method of data preprocessing for QRS detection, which is the first step in our way tofinal solution. We use Independent Component Analysis based "filter" that automatically chooses noise-free components. Selection is based on morfology of noisefree ECG components.
Název v anglickém jazyce
Processing Holter ECG signal corrupted with noise: Using ICA for QRS complex detection
Popis výsledku anglicky
Holter recording of electrocardiographic signal (ECG) is usually disturbed by noise added to measured useful signal due to e. g. worse contact skin-electrode, body movements, etc. Our general goal is to find at least some piece of informatik from ECG (inour case - positions of QRS complexes) in corrupted signal, on which common preprocessing methods fail. The main purpose of the article is description of an automatic method of data preprocessing for QRS detection, which is the first step in our way tofinal solution. We use Independent Component Analysis based "filter" that automatically chooses noise-free components. Selection is based on morfology of noisefree ECG components.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Conference Proceedings of The 3rd International Symposium on Applied Sciences in Biomedical and Communication Technologies
ISBN
978-1-4244-8132-3
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1-4
Název nakladatele
University of Rome "Tor Vergata"
Místo vydání
Rome
Místo konání akce
Rome
Datum konání akce
7. 11. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—