Device for long term measurement of heart rate
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F11%3A00187746" target="_blank" >RIV/68407700:21230/11:00187746 - isvavai.cz</a>
Výsledek na webu
<a href="http://dl.acm.org/citation.cfm?id=2093717&CFID=77923578&CFTOKEN=59249229" target="_blank" >http://dl.acm.org/citation.cfm?id=2093717&CFID=77923578&CFTOKEN=59249229</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1145/2093698.2093717" target="_blank" >10.1145/2093698.2093717</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Device for long term measurement of heart rate
Popis výsledku v původním jazyce
In this contribution, a device for long term measurement of heart rate is described. The device is created based on development kit STM32-Primer2. Heart rate frequency is calculated from selected electrocardiograph lead from the external module. The device allows simultaneous recoding of acceleration which makes is appropriate for physical activity detection of the test subject. The recorded data is saved on a memory card as signals in raw form, which can be used for subsequent processing in various research areas. Modular solution is suitable for connection of other modules. This device is designed for research and educational purposes in the field of medical devices and signal processing.
Název v anglickém jazyce
Device for long term measurement of heart rate
Popis výsledku anglicky
In this contribution, a device for long term measurement of heart rate is described. The device is created based on development kit STM32-Primer2. Heart rate frequency is calculated from selected electrocardiograph lead from the external module. The device allows simultaneous recoding of acceleration which makes is appropriate for physical activity detection of the test subject. The recorded data is saved on a memory card as signals in raw form, which can be used for subsequent processing in various research areas. Modular solution is suitable for connection of other modules. This device is designed for research and educational purposes in the field of medical devices and signal processing.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
In ACM Digital Library: Proceedings of 4th International Symposium on Applied Sciences in Biomedical and Communication Technologies
ISBN
978-1-4503-0913-4
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
ACM
Místo vydání
New York
Místo konání akce
Barcelona
Datum konání akce
26. 10. 2011
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—