Modular development telemonitoring system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00194702" target="_blank" >RIV/68407700:21230/12:00194702 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/TSP.2012.6256343" target="_blank" >http://dx.doi.org/10.1109/TSP.2012.6256343</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/TSP.2012.6256343" target="_blank" >10.1109/TSP.2012.6256343</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modular development telemonitoring system
Popis výsledku v původním jazyce
This paper presents a modular development telemonitoring system. The system consists of wireless communication and biosignal acquisition modules. These modules are connected to a control unit via an extension board. The control unit is based on STM32 EVOPrimer development kit. An integrated accelerometer is used for monitoring of subject's activity. The system features a signal processing and heart rate frequency computing algorithm. A memory card is used for saving the heart rate frequency. A heart arrhythmia alarm and an activity monitor are implemented in the system as well. The system has a simple alarm and a signal visualization program for PC. The modular solution is suitable for other biosignals acquisition and for miscellaneous means of wireless data transfer. The system provides raw signal data for further signal processing. This system was designed mainly for development, research and educational purposes in telemonitoring systems.
Název v anglickém jazyce
Modular development telemonitoring system
Popis výsledku anglicky
This paper presents a modular development telemonitoring system. The system consists of wireless communication and biosignal acquisition modules. These modules are connected to a control unit via an extension board. The control unit is based on STM32 EVOPrimer development kit. An integrated accelerometer is used for monitoring of subject's activity. The system features a signal processing and heart rate frequency computing algorithm. A memory card is used for saving the heart rate frequency. A heart arrhythmia alarm and an activity monitor are implemented in the system as well. The system has a simple alarm and a signal visualization program for PC. The modular solution is suitable for other biosignals acquisition and for miscellaneous means of wireless data transfer. The system provides raw signal data for further signal processing. This system was designed mainly for development, research and educational purposes in telemonitoring systems.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
35th International Conference Telecommunications and Signal Processing
ISBN
978-1-4673-1118-2
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
494-498
Název nakladatele
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Místo vydání
Brno
Místo konání akce
Prague
Datum konání akce
3. 7. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000308143100094