Popis výsledku v původním jazyce
Cardiotocography (CTG) is monitoring of fetal heart rate (FHR) and uterine contractions (TOCO). Since 1960's it is routinely used by obstetricians to detect fetal hypoxia. In theory, evaluation of the CTG in clinical setting is based on evaluation of macroscopic morphological features as suggested by internationally recognized FIGO guidelines. Though, based on our previous work it seems, that decision making process of obstetricians is not entirely based on macroscopic features and also nonlinear features invisible for naked eye were found significant. Therefore in this paper we present software application intended as a supporting tool for our ongoing research into the automatic evaluation of intrapartum cardiotocography records. Application that should give us better insight into expert-obstetrician decision making process.
Název v anglickém jazyce
CTG Annotator - Novel Tool for Better Insight into Expert-obstetrician Decision Making Processes
Popis výsledku anglicky
Cardiotocography (CTG) is monitoring of fetal heart rate (FHR) and uterine contractions (TOCO). Since 1960's it is routinely used by obstetricians to detect fetal hypoxia. In theory, evaluation of the CTG in clinical setting is based on evaluation of macroscopic morphological features as suggested by internationally recognized FIGO guidelines. Though, based on our previous work it seems, that decision making process of obstetricians is not entirely based on macroscopic features and also nonlinear features invisible for naked eye were found significant. Therefore in this paper we present software application intended as a supporting tool for our ongoing research into the automatic evaluation of intrapartum cardiotocography records. Application that should give us better insight into expert-obstetrician decision making process.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NT11124" target="_blank" >NT11124: Vliv hodnocení kardiotokografie pomocí metod umělé inteligence na kvalitu perinatální péče</a><br>
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFMBE Proceedings: World Congress on Medical Physics and Biomedical Engineering
ISBN
978-3-642-29304-7
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
3
Strana od-do
1280-1282
Název nakladatele
Springer
Místo vydání
Heidelberg
Místo konání akce
Beijing ( Peking)
Datum konání akce
26. 5. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—