Synchronous Phasors Monitoring System Application Possibilities
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00200010" target="_blank" >RIV/68407700:21230/12:00200010 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61388998:_____/12:00383473
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Synchronous Phasors Monitoring System Application Possibilities
Popis výsledku v původním jazyce
The paper deals with some tasks of advanced methods to achieve security and reliability of transmission power systems. There are discussed advanced principles and techniques in monitoring systems. The paper main part is devoted to possible applications of PMUs (Phasor Measurement Unit) and their integration into WAMPaC systems (Wide Area Monitoring, Protection and Control). Significant transmission system states were analyzed in several case studies. PMUs utilization for voltage monitoring is demonstrated for three cases - standard system state, high-load state and islanding. Here the attention is paid to the possibilities of power system observability improvement using measuring chain error elimination. Other possible applications in transmission systems include ampacity determination of transmission corridors, the calculation of line electrical parameters using synchrophasor measurement, state estimation issues and power system stability. The power system model was established for me
Název v anglickém jazyce
Synchronous Phasors Monitoring System Application Possibilities
Popis výsledku anglicky
The paper deals with some tasks of advanced methods to achieve security and reliability of transmission power systems. There are discussed advanced principles and techniques in monitoring systems. The paper main part is devoted to possible applications of PMUs (Phasor Measurement Unit) and their integration into WAMPaC systems (Wide Area Monitoring, Protection and Control). Significant transmission system states were analyzed in several case studies. PMUs utilization for voltage monitoring is demonstrated for three cases - standard system state, high-load state and islanding. Here the attention is paid to the possibilities of power system observability improvement using measuring chain error elimination. Other possible applications in transmission systems include ampacity determination of transmission corridors, the calculation of line electrical parameters using synchrophasor measurement, state estimation issues and power system stability. The power system model was established for me
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
27th Convention of Electrical and Electronics Engineers in Israel
ISBN
978-1-4673-4680-1
ISSN
—
e-ISSN
—
Počet stran výsledku
3
Strana od-do
1-3
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Eilat
Datum konání akce
14. 11. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce