Synchronous Phasors Monitoring System - Testing Project in the Czech Republic
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F12%3A00200098" target="_blank" >RIV/68407700:21230/12:00200098 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Synchronous Phasors Monitoring System - Testing Project in the Czech Republic
Popis výsledku v původním jazyce
The paper focuses on the issues of advanced methods to achieve security and reliability of electrical power systems, mainly focusing on transmission systems. Advanced principles and techniques in monitoring systems are discussed. The key part of the paper deals with application possibilities of PMUs (Phasor Measurement Unit) and their integration into WAMPaC systems (Wide Area Monitoring, Protection and Control). Assessment criteria are explained in a mathematical form and demonstrated in terms of casestudies. Significant power system states were analyzed in the case studies. PMUs usage for voltage phase monitoring is demonstrated for three cases - usual system state, high-load state and islanding. In this context the attention is paid to the possibilities of power system observability improvement using measuring chain error elimination.
Název v anglickém jazyce
Synchronous Phasors Monitoring System - Testing Project in the Czech Republic
Popis výsledku anglicky
The paper focuses on the issues of advanced methods to achieve security and reliability of electrical power systems, mainly focusing on transmission systems. Advanced principles and techniques in monitoring systems are discussed. The key part of the paper deals with application possibilities of PMUs (Phasor Measurement Unit) and their integration into WAMPaC systems (Wide Area Monitoring, Protection and Control). Assessment criteria are explained in a mathematical form and demonstrated in terms of casestudies. Significant power system states were analyzed in the case studies. PMUs usage for voltage phase monitoring is demonstrated for three cases - usual system state, high-load state and islanding. In this context the attention is paid to the possibilities of power system observability improvement using measuring chain error elimination.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů