Assessment of Power Systems with Doubly Fed Induction Generator Based Wind Turbines
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F13%3A00199185" target="_blank" >RIV/68407700:21230/13:00199185 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1166/asl.2013.4872" target="_blank" >http://dx.doi.org/10.1166/asl.2013.4872</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1166/asl.2013.4872" target="_blank" >10.1166/asl.2013.4872</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assessment of Power Systems with Doubly Fed Induction Generator Based Wind Turbines
Popis výsledku v původním jazyce
Connection and system integration of large scale wind power into the network systems has rose a number of important issues that must be evaluated in order to continually keep the power systems operation secure. It is therefore very important in planningand operation phases of power systems to perform and investigate the impact of wind power on the transient and small-signal stability. This paper briefly explores critical clearing time as a transient stability margin to evaluate the tested power systemswithout and with doubly fed induction generator based wind turbines. Maximum amplitude of the power swing, its settling time and voltage recovery in the system are also studied as margins. Simulations for transient stability analysis in this paper are performed using the Power System Simulator for Engineering software tools.
Název v anglickém jazyce
Assessment of Power Systems with Doubly Fed Induction Generator Based Wind Turbines
Popis výsledku anglicky
Connection and system integration of large scale wind power into the network systems has rose a number of important issues that must be evaluated in order to continually keep the power systems operation secure. It is therefore very important in planningand operation phases of power systems to perform and investigate the impact of wind power on the transient and small-signal stability. This paper briefly explores critical clearing time as a transient stability margin to evaluate the tested power systemswithout and with doubly fed induction generator based wind turbines. Maximum amplitude of the power swing, its settling time and voltage recovery in the system are also studied as margins. Simulations for transient stability analysis in this paper are performed using the Power System Simulator for Engineering software tools.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advanced Science Letters
ISSN
1936-6612
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
5
Strana od-do
811-815
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—