Virtual Sensors for Diagnostics of Valve
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F13%3A00206260" target="_blank" >RIV/68407700:21230/13:00206260 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Virtual Sensors for Diagnostics of Valve
Popis výsledku v původním jazyce
The new trend in the modern technical diagnostic tends to diagnose virtually any important part of a device with minimizing of number of the new sensors for doing this. Tnis effort leads to the idea of virtual sensors. Using indirect measurement and a model of diagnosed system, we can obtain information of system compoments status without necessity of new physical sensors. This paper suggests novel method for monitoring of electromagnetic valve proper function. The method is based on monitoring of valveswitching current waveform. This method is able to diagnose seizing of the valve, spring crack or defect of the valve coil. The incomplete valve operation can be also diagnosed as well. Proposed method is based on the comparison between measured currentwaveform during the valve switching with anticipated behavior, described by mathematic model of the diagnosed valve.
Název v anglickém jazyce
Virtual Sensors for Diagnostics of Valve
Popis výsledku anglicky
The new trend in the modern technical diagnostic tends to diagnose virtually any important part of a device with minimizing of number of the new sensors for doing this. Tnis effort leads to the idea of virtual sensors. Using indirect measurement and a model of diagnosed system, we can obtain information of system compoments status without necessity of new physical sensors. This paper suggests novel method for monitoring of electromagnetic valve proper function. The method is based on monitoring of valveswitching current waveform. This method is able to diagnose seizing of the valve, spring crack or defect of the valve coil. The incomplete valve operation can be also diagnosed as well. Proposed method is based on the comparison between measured currentwaveform during the valve switching with anticipated behavior, described by mathematic model of the diagnosed valve.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED2.1.00%2F03.0091" target="_blank" >ED2.1.00/03.0091: Univerzitní centrum energeticky efektivních budov (UCEEB)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
10TH INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND MACHINERY FAILURE PREVENTION TECHNOLOGIES CM2013/MFPT2013
ISBN
9781629939926
ISSN
—
e-ISSN
—
Počet stran výsledku
7
Strana od-do
—
Název nakladatele
Coxmoor Publishing Co.
Místo vydání
Oxfordshire
Místo konání akce
Krakov
Datum konání akce
18. 6. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—