Line Filtering for Surgical Tool Localization in 3D Ultrasound Images
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F13%3A00212572" target="_blank" >RIV/68407700:21230/13:00212572 - isvavai.cz</a>
Výsledek na webu
<a href="http://cmp.felk.cvut.cz/pub/cmp/articles/kybic/Uhercik-CBM2013.pdf" target="_blank" >http://cmp.felk.cvut.cz/pub/cmp/articles/kybic/Uhercik-CBM2013.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.compbiomed.2013.09.020" target="_blank" >10.1016/j.compbiomed.2013.09.020</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Line Filtering for Surgical Tool Localization in 3D Ultrasound Images
Popis výsledku v původním jazyce
We present a method for automatic surgical tool localization in 3D ultrasound images based on line filtering, voxel classification and model fitting. This could possibly provide assistance for biopsy needle or micro-electrode insertion, or a robotic system performing this insertion. The line-filtering method is first used to enhance the contrast of the 3D ultrasound image, then a classifier is chosen to separate the tool voxels, in order to reduce the number of outliers. The last step is Random Sample Consensus (RANSAC) model fitting. Experimental results on several different polyvinyl alcohol (PVA) cryogel data sets demonstrate that the failure rate of the method proposed herein is improved by at least 86% compared to the model-fitting RANSAC algorithm with axis accuracy better than 1 mm, at the expense of only a modest increase in computational effort. The results of this experiment show that this system could be useful for clinical applications.
Název v anglickém jazyce
Line Filtering for Surgical Tool Localization in 3D Ultrasound Images
Popis výsledku anglicky
We present a method for automatic surgical tool localization in 3D ultrasound images based on line filtering, voxel classification and model fitting. This could possibly provide assistance for biopsy needle or micro-electrode insertion, or a robotic system performing this insertion. The line-filtering method is first used to enhance the contrast of the 3D ultrasound image, then a classifier is chosen to separate the tool voxels, in order to reduce the number of outliers. The last step is Random Sample Consensus (RANSAC) model fitting. Experimental results on several different polyvinyl alcohol (PVA) cryogel data sets demonstrate that the failure rate of the method proposed herein is improved by at least 86% compared to the model-fitting RANSAC algorithm with axis accuracy better than 1 mm, at the expense of only a modest increase in computational effort. The results of this experiment show that this system could be useful for clinical applications.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP202%2F11%2F0111" target="_blank" >GAP202/11/0111: Automatická analýza obrazů nervové tkáně ze světelné a elektronové mikroskopie</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Computers in Biology and Medicine
ISSN
0010-4825
e-ISSN
—
Svazek periodika
43
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
2036-2045
Kód UT WoS článku
000329413800006
EID výsledku v databázi Scopus
—