Using SVC to Improve Voltage Stability of the Ghana Power Network
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F13%3A00212785" target="_blank" >RIV/68407700:21230/13:00212785 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27240/13:86096800
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Using SVC to Improve Voltage Stability of the Ghana Power Network
Popis výsledku v původním jazyce
This paper forms part of an ongoing system development of the Ghanaian power network. Preliminary studies have shown that the northern sector is venerable to voltage instability which has led to the proposed installation of STATCOM at Tamale. It is therefore necessary to assess the performance of the device when put in operation. Comparison had therefore been made between the use of STATCOM and Fixed Compensator. Line and generator contingencies as well as small signal disturbances analysis had been carried out. Voltage stability is improved with the installation of STATCOM as well as reduction in voltage oscillation during transient. Loadability limit of the system is also increased. Further evaluation targeted at the inter-tie with Burkina Faso has been proposed.
Název v anglickém jazyce
Using SVC to Improve Voltage Stability of the Ghana Power Network
Popis výsledku anglicky
This paper forms part of an ongoing system development of the Ghanaian power network. Preliminary studies have shown that the northern sector is venerable to voltage instability which has led to the proposed installation of STATCOM at Tamale. It is therefore necessary to assess the performance of the device when put in operation. Comparison had therefore been made between the use of STATCOM and Fixed Compensator. Line and generator contingencies as well as small signal disturbances analysis had been carried out. Voltage stability is improved with the installation of STATCOM as well as reduction in voltage oscillation during transient. Loadability limit of the system is also increased. Further evaluation targeted at the inter-tie with Burkina Faso has been proposed.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA03020095" target="_blank" >TA03020095: Minimalizace zpětných vlivů nelineárních a dynamických zátěží na napájecí síť</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Przeglad Elektrotechniczny
ISSN
0033-2097
e-ISSN
—
Svazek periodika
89
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
7
Strana od-do
47-53
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—