STATCOM Effect on Voltage Stability in Ghanaian Electrical Grid
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F14%3A00224518" target="_blank" >RIV/68407700:21230/14:00224518 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/EPE.2014.6839445" target="_blank" >http://dx.doi.org/10.1109/EPE.2014.6839445</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EPE.2014.6839445" target="_blank" >10.1109/EPE.2014.6839445</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
STATCOM Effect on Voltage Stability in Ghanaian Electrical Grid
Popis výsledku v původním jazyce
This paper deals with using STATCOM for voltage stability purposes which is analyzed on the Ghanaian power system development. Preliminary studies have shown that the northern sector is vulnerable to voltage instability which has led to the proposed installation of STATCOM in a key substation Tamale. It is therefore necessary to assess the performance of the device when put in operation. Comparison had therefore been made between the use of STATCOM and a fixed compensator. Line and generator contingencies as well as small signal disturbances analysis have been carried out. Voltage stability is improved with the installation of STATCOM but do not affect the interconnection between Ghana and Burkina Faso. Further evaluation focused on the inter-tie is proposed.
Název v anglickém jazyce
STATCOM Effect on Voltage Stability in Ghanaian Electrical Grid
Popis výsledku anglicky
This paper deals with using STATCOM for voltage stability purposes which is analyzed on the Ghanaian power system development. Preliminary studies have shown that the northern sector is vulnerable to voltage instability which has led to the proposed installation of STATCOM in a key substation Tamale. It is therefore necessary to assess the performance of the device when put in operation. Comparison had therefore been made between the use of STATCOM and a fixed compensator. Line and generator contingencies as well as small signal disturbances analysis have been carried out. Voltage stability is improved with the installation of STATCOM but do not affect the interconnection between Ghana and Burkina Faso. Further evaluation focused on the inter-tie is proposed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2014 15th International Scientific Conference on Electric Power Engineering
ISBN
978-1-4799-3807-0
ISSN
—
e-ISSN
2376-5623
Počet stran výsledku
6
Strana od-do
235-240
Název nakladatele
Vysoké učení technické v Brně
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
12. 5. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000358740100044