Utilization of Waveguide Applicators Combination for Electromagntic Field Focusing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F14%3A00217759" target="_blank" >RIV/68407700:21230/14:00217759 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/Radioelek.2014.6828446" target="_blank" >http://dx.doi.org/10.1109/Radioelek.2014.6828446</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/Radioelek.2014.6828446" target="_blank" >10.1109/Radioelek.2014.6828446</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Utilization of Waveguide Applicators Combination for Electromagntic Field Focusing
Popis výsledku v původním jazyce
The main goal of this article is to report on electromagnetic energy targeting (represented SAR) to muscle tissue affected by tumor. By the combination of four and six applicators we want to hit the most part of the tumor. We developed water filled waveguide applicator with stripline horn aperture suitable to get maximum SAR to the malignant tissue. To find suitable applicator position we used the EM field simulator SEMCAD Aletsch 14.8 from SPEAG, Schmidt & Partner Engineering AG, Switzerland. We used the mathematical software MATLAB to view simulation results. In the first part of this article we show the distribution of EM energy to the homogenous phantom with the dielectric parameters of human muscle in which we placed inhomogeneity as malignant tissue. We describe distribution of SAR values in phantoms with different widths. Further, we made SAR field optimization based on Generalized eigenvalue approach with the EM field simulator SEMCAD X. Then we used thermal simulation to show
Název v anglickém jazyce
Utilization of Waveguide Applicators Combination for Electromagntic Field Focusing
Popis výsledku anglicky
The main goal of this article is to report on electromagnetic energy targeting (represented SAR) to muscle tissue affected by tumor. By the combination of four and six applicators we want to hit the most part of the tumor. We developed water filled waveguide applicator with stripline horn aperture suitable to get maximum SAR to the malignant tissue. To find suitable applicator position we used the EM field simulator SEMCAD Aletsch 14.8 from SPEAG, Schmidt & Partner Engineering AG, Switzerland. We used the mathematical software MATLAB to view simulation results. In the first part of this article we show the distribution of EM energy to the homogenous phantom with the dielectric parameters of human muscle in which we placed inhomogeneity as malignant tissue. We describe distribution of SAR values in phantoms with different widths. Further, we made SAR field optimization based on Generalized eigenvalue approach with the EM field simulator SEMCAD X. Then we used thermal simulation to show
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA02010854" target="_blank" >TA02010854: Vývoj vysokovýkonových širokospektrálních zdrojů světla pro využití v medicíně</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
24th International Conference Radioelektronika 2014
ISBN
978-1-4799-3715-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Slovak University of Technology
Místo vydání
Bratislava
Místo konání akce
Bratislava
Datum konání akce
15. 4. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—