Long Term Heart Rate Monitoring Using Photoplethysmography Sensor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F14%3A00217850" target="_blank" >RIV/68407700:21230/14:00217850 - isvavai.cz</a>
Výsledek na webu
<a href="http://radio.feld.cvut.cz/conf/poster2014/" target="_blank" >http://radio.feld.cvut.cz/conf/poster2014/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Long Term Heart Rate Monitoring Using Photoplethysmography Sensor
Popis výsledku v původním jazyce
This paper presents a method for long-term monitoring of heart beat and motion reduction artifacts from PPG signal. Photoplethysmography (PPG) is a noninvasive measurement technique to monitoring variation in blood volume in tissue. It can provide an important information about cardio-respiratory system and assist to indicate serious diseases of cardiovascular system of patients. Long term monitoring in daily life requires miniaturized sensors and placement at the body to guaranteeing wearing comfort. Limiting factor can be distorted signal by motion artifacts. There are many techniques to reduce artifacts from PPG signal like moving average (MA), periodic moving average (PMAF), wavelet transform, least-mean square (LMS), variable-step LMS (VSLMS) etc.Motion of human body was measured simultaneously with the PPG by 3-axis MEMS accelerometer and it assists to recovery PPG signal and cancelled motion artifacts.
Název v anglickém jazyce
Long Term Heart Rate Monitoring Using Photoplethysmography Sensor
Popis výsledku anglicky
This paper presents a method for long-term monitoring of heart beat and motion reduction artifacts from PPG signal. Photoplethysmography (PPG) is a noninvasive measurement technique to monitoring variation in blood volume in tissue. It can provide an important information about cardio-respiratory system and assist to indicate serious diseases of cardiovascular system of patients. Long term monitoring in daily life requires miniaturized sensors and placement at the body to guaranteeing wearing comfort. Limiting factor can be distorted signal by motion artifacts. There are many techniques to reduce artifacts from PPG signal like moving average (MA), periodic moving average (PMAF), wavelet transform, least-mean square (LMS), variable-step LMS (VSLMS) etc.Motion of human body was measured simultaneously with the PPG by 3-axis MEMS accelerometer and it assists to recovery PPG signal and cancelled motion artifacts.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
POSTER 2014 - 18th International Student Conference on Electrical Engineering
ISBN
978-80-01-05499-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Czech Technical University
Místo vydání
Prague
Místo konání akce
Praha
Datum konání akce
15. 5. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—