Low Dimensional Manifold Embedding for Scattering Coefficients of Intrapartum Fetal Heart Rate Variability
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F14%3A00222186" target="_blank" >RIV/68407700:21230/14:00222186 - isvavai.cz</a>
Výsledek na webu
<a href="http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6945086" target="_blank" >http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6945086</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/EMBC.2014.6945086" target="_blank" >10.1109/EMBC.2014.6945086</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Low Dimensional Manifold Embedding for Scattering Coefficients of Intrapartum Fetal Heart Rate Variability
Popis výsledku v původním jazyce
Intrapartum fetal surveillance for early detection of fetal acidosis in clinical practice focuses on reducing neonatal morbidity via early detection. It is the subject of ongoing research studies attempting notably to improve detection performance by reducing false positive rate. In that context, the present contribution tailors to fetal heart rate variability analysis a graph-based dimensionality reduction procedure performed on scattering coefficients. Applied to a high quality and well-documented database constituted by obstetricians from a French academic hospital, the low dimensional embedding enables to distinguish between the temporal dynamics of healthy and acidotic fetuses, as well as to achieve satisfactory detection performance detection compared to those obtained by the clinical-benchmark FIGO criteria.
Název v anglickém jazyce
Low Dimensional Manifold Embedding for Scattering Coefficients of Intrapartum Fetal Heart Rate Variability
Popis výsledku anglicky
Intrapartum fetal surveillance for early detection of fetal acidosis in clinical practice focuses on reducing neonatal morbidity via early detection. It is the subject of ongoing research studies attempting notably to improve detection performance by reducing false positive rate. In that context, the present contribution tailors to fetal heart rate variability analysis a graph-based dimensionality reduction procedure performed on scattering coefficients. Applied to a high quality and well-documented database constituted by obstetricians from a French academic hospital, the low dimensional embedding enables to distinguish between the temporal dynamics of healthy and acidotic fetuses, as well as to achieve satisfactory detection performance detection compared to those obtained by the clinical-benchmark FIGO criteria.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
ISBN
978-1-4244-7929-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
6373-6376
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Chicago
Datum konání akce
26. 8. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—