High Resolution Range Imaging Via Model-based Compressed Sensing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F15%3A00230958" target="_blank" >RIV/68407700:21230/15:00230958 - isvavai.cz</a>
Výsledek na webu
<a href="http://piers.org/piersproceedings/download.php?file=cGllcnMyMDE1UHJhZ3VlfDFBM2JfMDI0OC5wZGZ8MTUwMjAyMDUxNTQw" target="_blank" >http://piers.org/piersproceedings/download.php?file=cGllcnMyMDE1UHJhZ3VlfDFBM2JfMDI0OC5wZGZ8MTUwMjAyMDUxNTQw</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High Resolution Range Imaging Via Model-based Compressed Sensing
Popis výsledku v původním jazyce
The paper proposes a method for high resolution range imaging at millimeter wave frequencies (85 GHz to 100 GHz) based on model-based compressed sensing (CS). A detailed description of the underlying CS-theory, the experimental setup and radar sensor arepresented along with experimental results for one-dimensional range imaging. The proposed method is based on motorized reference measurements, which form the dictionary matrix for subsequent CS-processing. These reference measurements are tested againstmeasurements from a glass fiber reinforced polymer (GFRP) component. A comparison of the CS-processed data to a classical Fourier-domain analysis revealed superior ranging performance of the CS-approach at the expense of a higher signal processing load.
Název v anglickém jazyce
High Resolution Range Imaging Via Model-based Compressed Sensing
Popis výsledku anglicky
The paper proposes a method for high resolution range imaging at millimeter wave frequencies (85 GHz to 100 GHz) based on model-based compressed sensing (CS). A detailed description of the underlying CS-theory, the experimental setup and radar sensor arepresented along with experimental results for one-dimensional range imaging. The proposed method is based on motorized reference measurements, which form the dictionary matrix for subsequent CS-processing. These reference measurements are tested againstmeasurements from a glass fiber reinforced polymer (GFRP) component. A comparison of the CS-processed data to a classical Fourier-domain analysis revealed superior ranging performance of the CS-approach at the expense of a higher signal processing load.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of PIERS 2015 in Prague
ISBN
978-1-934142-30-1
ISSN
1559-9450
e-ISSN
—
Počet stran výsledku
5
Strana od-do
248-252
Název nakladatele
Electromagnetics Academy
Místo vydání
Cambridge
Místo konání akce
Praha
Datum konání akce
6. 7. 2015
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—