PVD-grown antibacterial Ag-TiN fi lms on piezoelectric PVDF substrates for sensor applications
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F15%3A00233729" target="_blank" >RIV/68407700:21230/15:00233729 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.surfcoat.2015.09.057" target="_blank" >http://dx.doi.org/10.1016/j.surfcoat.2015.09.057</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.surfcoat.2015.09.057" target="_blank" >10.1016/j.surfcoat.2015.09.057</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
PVD-grown antibacterial Ag-TiN fi lms on piezoelectric PVDF substrates for sensor applications
Popis výsledku v původním jazyce
This work reports on Ti-1 _ Ag-x(x) and Ag-TiNx electrodes deposited by dc/pulsed dc magnetron sputtering at room temperature on poly (vinylidene fluoride) (PVDF) with the purpose of developing sensors for prosthesis. In Ti-1 _ Ag-x(x) electrodes, silvercontent was varied from 0-100 at.%; and for Ag-TiNx electrodes, the nitrogen content was varied between 34 and 43 at.% and the Ti/Ag ratio changed from 12.2 to 5.2. The antibacterial activity of the samples was assessed by the agar diffusion method. Interestingly, samples from the Ag-TiNx series presented antibacterial activity, in contrast to the samples from Ti-1 _ Ag-x(x) series. XPS results showed that the as-deposited samples from the Ag-TiNx series exhibited silver clusters smaller than 4 nm. Inorder to deepen the results obtained, samples were analysed after the Halo test (antibacterial test), and XPS analyses showed the disappearance of these Ag clusters in agreement with the SEM results, which displayed a visible aggregation
Název v anglickém jazyce
PVD-grown antibacterial Ag-TiN fi lms on piezoelectric PVDF substrates for sensor applications
Popis výsledku anglicky
This work reports on Ti-1 _ Ag-x(x) and Ag-TiNx electrodes deposited by dc/pulsed dc magnetron sputtering at room temperature on poly (vinylidene fluoride) (PVDF) with the purpose of developing sensors for prosthesis. In Ti-1 _ Ag-x(x) electrodes, silvercontent was varied from 0-100 at.%; and for Ag-TiNx electrodes, the nitrogen content was varied between 34 and 43 at.% and the Ti/Ag ratio changed from 12.2 to 5.2. The antibacterial activity of the samples was assessed by the agar diffusion method. Interestingly, samples from the Ag-TiNx series presented antibacterial activity, in contrast to the samples from Ti-1 _ Ag-x(x) series. XPS results showed that the as-deposited samples from the Ag-TiNx series exhibited silver clusters smaller than 4 nm. Inorder to deepen the results obtained, samples were analysed after the Halo test (antibacterial test), and XPS analyses showed the disappearance of these Ag clusters in agreement with the SEM results, which displayed a visible aggregation
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JK - Koroze a povrchové úpravy materiálu
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/EE2.3.30.0034" target="_blank" >EE2.3.30.0034: Podpora zkvalitnění týmů výzkumu a vývoje a rozvoj intersektorální mobility na ČVUT v Praze</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Surface and Coatings Technology
ISSN
0257-8972
e-ISSN
—
Svazek periodika
281
Číslo periodika v rámci svazku
November
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
117-124
Kód UT WoS článku
000366072200015
EID výsledku v databázi Scopus
2-s2.0-84947052020