Adaptive Protection Scheme Used for Distributed Generation System Switched into Island Mode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F15%3A00235838" target="_blank" >RIV/68407700:21230/15:00235838 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Adaptive Protection Scheme Used for Distributed Generation System Switched into Island Mode
Popis výsledku v původním jazyce
This paper proposes setting algorithm for adaptive protection scheme based on directional overcurrent protections with inverse-time characteristics. Use example of an adaptive algorithm is illustrated on distributed generation system switched into islandmode. After switching the grid into island mode, system-short circuit conditions get usually rapidly changed, and new setting must be calculated and set into adaptive protections. Each protection is set individually due to topical grid configuration through communication line by superior system. Superior system includes model of grid and allows for computation of short-circuit currents in all branches and nodes of the system. Advantage of protection scheme based on directional protections with inverse-time characteristics is certain resistance to small changes in short-circuit currents and possible protection of the grid in case of communication failure with superior system.
Název v anglickém jazyce
Adaptive Protection Scheme Used for Distributed Generation System Switched into Island Mode
Popis výsledku anglicky
This paper proposes setting algorithm for adaptive protection scheme based on directional overcurrent protections with inverse-time characteristics. Use example of an adaptive algorithm is illustrated on distributed generation system switched into islandmode. After switching the grid into island mode, system-short circuit conditions get usually rapidly changed, and new setting must be calculated and set into adaptive protections. Each protection is set individually due to topical grid configuration through communication line by superior system. Superior system includes model of grid and allows for computation of short-circuit currents in all branches and nodes of the system. Advantage of protection scheme based on directional protections with inverse-time characteristics is certain resistance to small changes in short-circuit currents and possible protection of the grid in case of communication failure with superior system.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JE - Nejaderná energetika, spotřeba a užití energie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 8th International Scientific Symposium on Electrical Power Engineering ELEKTROENERGETIKA 2015
ISBN
978-80-553-2187-5
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
560-563
Název nakladatele
TU Košice
Místo vydání
Košice
Místo konání akce
Stará Lesná
Datum konání akce
16. 9. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—