Correctness of bioimpedance data for body composition obtained by BIA approach in various external conditions
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F15%3A00238162" target="_blank" >RIV/68407700:21230/15:00238162 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62690094:18470/15:50004363
Výsledek na webu
<a href="http://link.springer.com/chapter/10.1007%2F978-3-319-19387-8_320" target="_blank" >http://link.springer.com/chapter/10.1007%2F978-3-319-19387-8_320</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/978-3-319-19387-8_320" target="_blank" >10.1007/978-3-319-19387-8_320</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Correctness of bioimpedance data for body composition obtained by BIA approach in various external conditions
Popis výsledku v původním jazyce
This paper presents our ongoing research in a field of body composition obtained by body impedance analysis. In this work we were focused on changes in bioimpedance in dependence on change of measurement external conditions. This paper also deals with question if data obtained from this method are enough informative with ought any information about the performed measurement. We discovered that it is crucial to have information about the whole measurement procedure and that operator that is performing such measurement should know exact type of device that is used for measurements. Influence of specific conditions did not statistically changed results of calculated values. However in directly measured values resistance and reactance at high frequencies (250 kHz and 500 kHz) were found statistically significant changes (P=0,05) for highly conductive gel. Overall was concluded that external conditions that can be normally encountered at laboratories do not have effect on obtained values. H
Název v anglickém jazyce
Correctness of bioimpedance data for body composition obtained by BIA approach in various external conditions
Popis výsledku anglicky
This paper presents our ongoing research in a field of body composition obtained by body impedance analysis. In this work we were focused on changes in bioimpedance in dependence on change of measurement external conditions. This paper also deals with question if data obtained from this method are enough informative with ought any information about the performed measurement. We discovered that it is crucial to have information about the whole measurement procedure and that operator that is performing such measurement should know exact type of device that is used for measurements. Influence of specific conditions did not statistically changed results of calculated values. However in directly measured values resistance and reactance at high frequencies (250 kHz and 500 kHz) were found statistically significant changes (P=0,05) for highly conductive gel. Overall was concluded that external conditions that can be normally encountered at laboratories do not have effect on obtained values. H
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
World Congress on Medical Physics and Biomedical Engineering, June 7-12, 2015, Toronto, Canada
ISBN
978-3-319-19387-8
ISSN
1680-0737
e-ISSN
—
Počet stran výsledku
4
Strana od-do
1317-1320
Název nakladatele
Springer International Publishing AG
Místo vydání
Cham
Místo konání akce
Toronto, Canada
Datum konání akce
7. 6. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—