Sensitivity of microwave ablation models to tissue biophysical properties: A first step toward probabilistic modeling and treatment planning.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F16%3A00242811" target="_blank" >RIV/68407700:21230/16:00242811 - isvavai.cz</a>
Výsledek na webu
<a href="http://scitation.aip.org/content/aapm/journal/medphys/43/5/10.1118/1.4947482" target="_blank" >http://scitation.aip.org/content/aapm/journal/medphys/43/5/10.1118/1.4947482</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1118/1.4947482" target="_blank" >10.1118/1.4947482</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sensitivity of microwave ablation models to tissue biophysical properties: A first step toward probabilistic modeling and treatment planning.
Popis výsledku v původním jazyce
Computational models of microwave ablation are widely used during the design optimization of novel devices and are under consideration for patient-specific treatment planning. The objective of this study was to assess the sensitivity of computational models to tissue biophysical properties. The Morris method was employed to assess the global sensitivity of the coupled EM model, which was implemented with the finite element method (FEM). The FEM model incorporated temperature dependencies of tissue physical properties. Furthermore, the sensitivity results were statistically analyzed and absolute influence of each input parameter was quantified. A framework for systematically incorporating model uncertainties for treatment planning was suggested. Tissue dielectric parameters, specifically relative permittivity, effective conductivity, and the threshold temperature at which they transitioned to lower values, were identified as the most influential parameters for the shape of the ablation zone and antenna impedance matching. Of the thermal parameters considered in this study, the nominal blood perfusion rate and the temperature interval across which the tissue changes phase were identified as the most influential. The latent heat of tissue water vaporization and the volumetric heat capacity of the vaporized tissue were recognized as the least influential parameters. Based on the evaluation of absolute changes, the most important parameter (perfusion) had approximately 40.23 times greater influence on ablation area than the least important parameter (volumetric heat capacity of vaporized tissue). Another significant input parameter (permittivity) had 22.26 times higher influence on the deviation of ablation edge shape from a sphere than one of the less important parameters (latent heat of liver tissue vaporization).
Název v anglickém jazyce
Sensitivity of microwave ablation models to tissue biophysical properties: A first step toward probabilistic modeling and treatment planning.
Popis výsledku anglicky
Computational models of microwave ablation are widely used during the design optimization of novel devices and are under consideration for patient-specific treatment planning. The objective of this study was to assess the sensitivity of computational models to tissue biophysical properties. The Morris method was employed to assess the global sensitivity of the coupled EM model, which was implemented with the finite element method (FEM). The FEM model incorporated temperature dependencies of tissue physical properties. Furthermore, the sensitivity results were statistically analyzed and absolute influence of each input parameter was quantified. A framework for systematically incorporating model uncertainties for treatment planning was suggested. Tissue dielectric parameters, specifically relative permittivity, effective conductivity, and the threshold temperature at which they transitioned to lower values, were identified as the most influential parameters for the shape of the ablation zone and antenna impedance matching. Of the thermal parameters considered in this study, the nominal blood perfusion rate and the temperature interval across which the tissue changes phase were identified as the most influential. The latent heat of tissue water vaporization and the volumetric heat capacity of the vaporized tissue were recognized as the least influential parameters. Based on the evaluation of absolute changes, the most important parameter (perfusion) had approximately 40.23 times greater influence on ablation area than the least important parameter (volumetric heat capacity of vaporized tissue). Another significant input parameter (permittivity) had 22.26 times higher influence on the deviation of ablation edge shape from a sphere than one of the less important parameters (latent heat of liver tissue vaporization).
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JC - Počítačový hardware a software
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Medical Physics
ISSN
0094-2405
e-ISSN
—
Svazek periodika
2016(43)
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
13
Strana od-do
2649-2661
Kód UT WoS článku
000378924200063
EID výsledku v databázi Scopus
2-s2.0-84973639336