Measurement of ionizing particles by the PH32 chip
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F16%3A00311871" target="_blank" >RIV/68407700:21230/16:00311871 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21340/16:00311871
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-84994156549&origin=resultslist&sort=plf-f&src=s&sid=59D2F2E1F92C114A9E03F9CF6D5B59BB.wsnAw8kcdt7IPYLO0V48gA%3a300&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2855471910100%29&relpos=2&citeCnt=0&searchTerm=" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-84994156549&origin=resultslist&sort=plf-f&src=s&sid=59D2F2E1F92C114A9E03F9CF6D5B59BB.wsnAw8kcdt7IPYLO0V48gA%3a300&sot=autdocs&sdt=autdocs&sl=18&s=AU-ID%2855471910100%29&relpos=2&citeCnt=0&searchTerm=</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Measurement of ionizing particles by the PH32 chip
Popis výsledku v původním jazyce
The PH32 readout chip for the measurement of X-rays, beta radiation and ions including alpha particles has been developed recently. The chip was manufactured using a commercial 180 nm CMOS process and can be used in the dose rate measurement and the basic spectroscopy. It is able to measure generated charge as well as counting hits from a silicon sensor in two operation modes. The low range mode is able to measure generated charge in the range from 7 ke- to 40 ke- for soft X-rays and beta radiation, the high range mode in the range from 200 ke- to 5 Me- for alpha particles. The measurement accuracy is about 1700 e- for the chip calibration charge of 16 ke- and 37 ke- for the calibration charge of 3 Me-. The measurements presented in this paper are focused on the channel response to the injected charge including linearity, gain, channel uniformity, noise and dispersion. The energetic spectrum of 241 Am and 239Pu is presented together with the ability to measure the dose rate in the range of 8-orders of magnitude.
Název v anglickém jazyce
Measurement of ionizing particles by the PH32 chip
Popis výsledku anglicky
The PH32 readout chip for the measurement of X-rays, beta radiation and ions including alpha particles has been developed recently. The chip was manufactured using a commercial 180 nm CMOS process and can be used in the dose rate measurement and the basic spectroscopy. It is able to measure generated charge as well as counting hits from a silicon sensor in two operation modes. The low range mode is able to measure generated charge in the range from 7 ke- to 40 ke- for soft X-rays and beta radiation, the high range mode in the range from 200 ke- to 5 Me- for alpha particles. The measurement accuracy is about 1700 e- for the chip calibration charge of 16 ke- and 37 ke- for the calibration charge of 3 Me-. The measurements presented in this paper are focused on the channel response to the injected charge including linearity, gain, channel uniformity, noise and dispersion. The energetic spectrum of 241 Am and 239Pu is presented together with the ability to measure the dose rate in the range of 8-orders of magnitude.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TE01020069" target="_blank" >TE01020069: Progresívní detekční systémy ionizujícího záření</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2015 IEEE Nuclear Science Symposium and Medical Imaging Conference
ISBN
9781467398626
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
1-5
Název nakladatele
IEEE
Místo vydání
—
Místo konání akce
San Diego
Datum konání akce
31. 10. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—