Timepix detector as a tool for X-ray and gamma dosimetry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F86652052%3A_____%2F17%3AN0000051" target="_blank" >RIV/86652052:_____/17:N0000051 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21220/17:00319504 RIV/68407700:21670/17:00319504
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.radmeas.2017.10.012" target="_blank" >http://dx.doi.org/10.1016/j.radmeas.2017.10.012</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radmeas.2017.10.012" target="_blank" >10.1016/j.radmeas.2017.10.012</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Timepix detector as a tool for X-ray and gamma dosimetry
Popis výsledku v původním jazyce
We present a concept of using Timepix detector for real-time and simultaneous measurements of various external dosimetry and operational quantities in X-ray/gamma fields with broad range of air kerma rates ranging from natural background levels to the order of Gy·h−1, including intensive pulsed sources used in medicine. Timepix is a hybrid semiconductor detector of ionizing radiation which can visualize tracks of particles interacting in the semiconductor pixelated sensor bump bonded to the Timepix readout chip. Energy deposited in the individual pixels and properties of these tracks enable us to classify the incident radiation and to assign the correct conversion coefficient between a number of detected events and the desired quantity, e.g. an ambient dose equivalent rate. This paper shows calibration measurements of such dosemeter and discusses its properties.
Název v anglickém jazyce
Timepix detector as a tool for X-ray and gamma dosimetry
Popis výsledku anglicky
We present a concept of using Timepix detector for real-time and simultaneous measurements of various external dosimetry and operational quantities in X-ray/gamma fields with broad range of air kerma rates ranging from natural background levels to the order of Gy·h−1, including intensive pulsed sources used in medicine. Timepix is a hybrid semiconductor detector of ionizing radiation which can visualize tracks of particles interacting in the semiconductor pixelated sensor bump bonded to the Timepix readout chip. Energy deposited in the individual pixels and properties of these tracks enable us to classify the incident radiation and to assign the correct conversion coefficient between a number of detected events and the desired quantity, e.g. an ambient dose equivalent rate. This paper shows calibration measurements of such dosemeter and discusses its properties.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Measurements
ISSN
1350-4487
e-ISSN
—
Svazek periodika
107
Číslo periodika v rámci svazku
December
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
39-42