Subjective speech quality measurement repeatability: comparison of laboratory test results
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F17%3A00302964" target="_blank" >RIV/68407700:21230/17:00302964 - isvavai.cz</a>
Výsledek na webu
<a href="http://link.springer.com/article/10.1007/s10772-016-9389-6" target="_blank" >http://link.springer.com/article/10.1007/s10772-016-9389-6</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10772-016-9389-6" target="_blank" >10.1007/s10772-016-9389-6</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Subjective speech quality measurement repeatability: comparison of laboratory test results
Popis výsledku v původním jazyce
This article reports on a multi-lab subjective listening experiment aiming at inter-lab and intra-lab test results repeatability verification. An identical set of speech samples corresponding to contemporary networks has been tested by three independent labs deploying ITU-T P.835 methodology. The tests results have been compared regarding Pearson correlation, RMSE, RMSE* and numbers of opposite pair-wise comparisons. The results show the level of inter-lab and intra-lab repeatability in the case of identical test speech samples utilization and thus confirm the subjective tests are highly repeatable in case they follow recommendation requirements strictly. The tests also show differences in results in case subject expectations are set differently using a wider set of test speech samples (as presented in one of the labs).
Název v anglickém jazyce
Subjective speech quality measurement repeatability: comparison of laboratory test results
Popis výsledku anglicky
This article reports on a multi-lab subjective listening experiment aiming at inter-lab and intra-lab test results repeatability verification. An identical set of speech samples corresponding to contemporary networks has been tested by three independent labs deploying ITU-T P.835 methodology. The tests results have been compared regarding Pearson correlation, RMSE, RMSE* and numbers of opposite pair-wise comparisons. The results show the level of inter-lab and intra-lab repeatability in the case of identical test speech samples utilization and thus confirm the subjective tests are highly repeatable in case they follow recommendation requirements strictly. The tests also show differences in results in case subject expectations are set differently using a wider set of test speech samples (as presented in one of the labs).
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20203 - Telecommunications
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Speech Technology
ISSN
1381-2416
e-ISSN
1572-8110
Svazek periodika
20
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
AT - Rakouská republika
Počet stran výsledku
6
Strana od-do
69-74
Kód UT WoS článku
000394370400006
EID výsledku v databázi Scopus
2-s2.0-84994226059