Feasibility of Pancreatic Cancer Treatment by Aid of Microwave Interstitial Hyperthermia Applicators
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F19%3A00335090" target="_blank" >RIV/68407700:21230/19:00335090 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68407700:21460/19:00335090
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Feasibility of Pancreatic Cancer Treatment by Aid of Microwave Interstitial Hyperthermia Applicators
Popis výsledku v původním jazyce
Main aim of this paper is to study (based on numerical simulations) technical feasibility of pancreatic cancer treatment by aid of microwave hyperthermia – using array of 4 microwave helix interstitial hyperthermia applicators. These simulations were performed in EM field simulator SEMCAD X for 3 different ISM frequencies: 434, 915 and 2450 MHz. Comparison of SAR distribution value (Specific Absorption Rate) simulated on these 3 frequencies is discussed. "High-Resolution Human Models for Simulations: Virtual Population" were used for this study. Final aim of this feasibility study was to identify most suitable frequency (from those mentioned above) for the pancreatic cancer treatment. Keywords-Microwave hyperthermia, pancreatic cancer treatment, interstitial helix applicator, BPH, hyperthermia applicators.
Název v anglickém jazyce
Feasibility of Pancreatic Cancer Treatment by Aid of Microwave Interstitial Hyperthermia Applicators
Popis výsledku anglicky
Main aim of this paper is to study (based on numerical simulations) technical feasibility of pancreatic cancer treatment by aid of microwave hyperthermia – using array of 4 microwave helix interstitial hyperthermia applicators. These simulations were performed in EM field simulator SEMCAD X for 3 different ISM frequencies: 434, 915 and 2450 MHz. Comparison of SAR distribution value (Specific Absorption Rate) simulated on these 3 frequencies is discussed. "High-Resolution Human Models for Simulations: Virtual Population" were used for this study. Final aim of this feasibility study was to identify most suitable frequency (from those mentioned above) for the pancreatic cancer treatment. Keywords-Microwave hyperthermia, pancreatic cancer treatment, interstitial helix applicator, BPH, hyperthermia applicators.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GJ17-00477Y" target="_blank" >GJ17-00477Y: Fyzikální podstata interakcí EM pole generovaného MTM strukturami s lidským tělem a studie možnosti jejich perspektivního využití v medicíně</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of European Microwave Conference in Central Europe, EuMCE 2019
ISBN
9782874870675
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
444-447
Název nakladatele
European Microwave Association (EuMA)
Místo vydání
Louvain-la-Neuve
Místo konání akce
Praha
Datum konání akce
13. 5. 2019
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—