Photovoltaic panel Spice modelling
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F20%3A00345555" target="_blank" >RIV/68407700:21230/20:00345555 - isvavai.cz</a>
Výsledek na webu
<a href="http://hdl.handle.net/10467/92483" target="_blank" >http://hdl.handle.net/10467/92483</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Photovoltaic panel Spice modelling
Popis výsledku v původním jazyce
The paper presents a universal Spice model that can be used for modelling the photovoltaic panels (PV) – namely the DC characteristics. The model was built on simplified schematic and fitting its parameters to the measured data. There were developed two types of the models – the simple model and the full model. The simple model is valid only for PVs with constant width of the PN junction strip (only the number and length are scalable). The full model allows user to set also the PN junction’s width. The simple model exhibits better accuracy, typically better than 5 %, while the full model’s accuracy is typically lower than 15 % (for illumination in the range from 20 lx to 2000 lx).
Název v anglickém jazyce
Photovoltaic panel Spice modelling
Popis výsledku anglicky
The paper presents a universal Spice model that can be used for modelling the photovoltaic panels (PV) – namely the DC characteristics. The model was built on simplified schematic and fitting its parameters to the measured data. There were developed two types of the models – the simple model and the full model. The simple model is valid only for PVs with constant width of the PN junction strip (only the number and length are scalable). The full model allows user to set also the PN junction’s width. The simple model exhibits better accuracy, typically better than 5 %, while the full model’s accuracy is typically lower than 15 % (for illumination in the range from 20 lx to 2000 lx).
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/7D19001" target="_blank" >7D19001: SACON - Smart Access Control for Smart Buildings</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
ElectroScope
ISSN
1802-4564
e-ISSN
1802-4564
Svazek periodika
2020
Číslo periodika v rámci svazku
I.
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
3
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—