Stabilized magnetic vacuum using a rotating fluxgate sensor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F20%3A00345810" target="_blank" >RIV/68407700:21230/20:00345810 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/SENSORS47125.2020.9278793" target="_blank" >https://doi.org/10.1109/SENSORS47125.2020.9278793</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/SENSORS47125.2020.9278793" target="_blank" >10.1109/SENSORS47125.2020.9278793</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stabilized magnetic vacuum using a rotating fluxgate sensor
Popis výsledku v původním jazyce
We present an effective zero-field system utilizing a rotating, single-axis fluxgate sensor to establish and maintain a magnetic vacuum in triaxial coils. With the help of a low-noise fluxgate sensor rotating at a frequency of 1 Hz, we were able to set the magnetic zero in the horizontal plane to or below 0.5 nT, which is 10 ppm of the local magnetic field, or 100 dB suppression. With the help of an additional triaxial sensor at a 2.5-m distance, we were able to maintain the magnetic zero to about 1 nT within 30-minutes suppressing field variations and disturbances. Such a system allows for precise magnetic calibrations, paleomagnetic experiments or other tasks where magnetic vacuum is beneficial or required.
Název v anglickém jazyce
Stabilized magnetic vacuum using a rotating fluxgate sensor
Popis výsledku anglicky
We present an effective zero-field system utilizing a rotating, single-axis fluxgate sensor to establish and maintain a magnetic vacuum in triaxial coils. With the help of a low-noise fluxgate sensor rotating at a frequency of 1 Hz, we were able to set the magnetic zero in the horizontal plane to or below 0.5 nT, which is 10 ppm of the local magnetic field, or 100 dB suppression. With the help of an additional triaxial sensor at a 2.5-m distance, we were able to maintain the magnetic zero to about 1 nT within 30-minutes suppressing field variations and disturbances. Such a system allows for precise magnetic calibrations, paleomagnetic experiments or other tasks where magnetic vacuum is beneficial or required.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2020 IEEE SENSORS Proceedings
ISBN
978-1-7281-6801-2
ISSN
—
e-ISSN
2168-9229
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
IEEE Sensors Council
Místo vydání
Orlando, Florida
Místo konání akce
Rotterdam
Datum konání akce
25. 10. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce