Programmable Partial Discharge Calibrator Based on Current Source
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F25%3A00386266" target="_blank" >RIV/68407700:21230/25:00386266 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/11218300" target="_blank" >https://ieeexplore.ieee.org/document/11218300</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/CEIDP61707.2025.11218300" target="_blank" >10.1109/CEIDP61707.2025.11218300</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Programmable Partial Discharge Calibrator Based on Current Source
Popis výsledku v původním jazyce
Standard partial discharge calibrators generate pulses with defined charge values by deriving a rectangular voltage pulse through a series-connected capacitor with a low capacitance value. The output pulse of the calibrator then has a double exponential waveform with different rise and tail times. However, the resulting charge value is affected by the parasitic capacitance of the circuit and the capacitance of the objects or samples being measured. Many of these parasitic effects cannot be determined, causing variations between the set and injected charges. Calibration is limited for this reason and generally only limited inference can be made on the actual charge values. Solution based on the generation of a partial discharge pulse by a current source instead of generating the pulse by deriving a voltage step is presented. This solution brings undeniable advantages with respect to the classical solution, but on the other hand requires higher demands for the technical design.
Název v anglickém jazyce
Programmable Partial Discharge Calibrator Based on Current Source
Popis výsledku anglicky
Standard partial discharge calibrators generate pulses with defined charge values by deriving a rectangular voltage pulse through a series-connected capacitor with a low capacitance value. The output pulse of the calibrator then has a double exponential waveform with different rise and tail times. However, the resulting charge value is affected by the parasitic capacitance of the circuit and the capacitance of the objects or samples being measured. Many of these parasitic effects cannot be determined, causing variations between the set and injected charges. Calibration is limited for this reason and generally only limited inference can be made on the actual charge values. Solution based on the generation of a partial discharge pulse by a current source instead of generating the pulse by deriving a voltage step is presented. This solution brings undeniable advantages with respect to the classical solution, but on the other hand requires higher demands for the technical design.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2025 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)
ISBN
979-8-3315-8902-8
ISSN
0084-9162
e-ISSN
—
Počet stran výsledku
4
Strana od-do
535-538
Název nakladatele
Institute of Electrical and Electronics Engineers
Místo vydání
Piscataway
Místo konání akce
Manchester
Datum konání akce
14. 9. 2025
Typ akce podle státní příslušnosti
WRD - Celosvětová akce