Comparative Analysis of Methods for Partial Discharge Calibrator Performance
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F24%3A00378094" target="_blank" >RIV/68407700:21230/24:00378094 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1109/ICHVE61955.2024.10676179" target="_blank" >https://doi.org/10.1109/ICHVE61955.2024.10676179</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICHVE61955.2024.10676179" target="_blank" >10.1109/ICHVE61955.2024.10676179</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparative Analysis of Methods for Partial Discharge Calibrator Performance
Popis výsledku v původním jazyce
Partial discharge (PD) calibrators are utilized to determine the conversion constant of a measurement system employed to quantify partial discharge quantities. Since the characteristics of such calibrators may change over time, it is essential to conduct periodic checks on these characteristics at regular intervals and after any repairs. The fundamental parameters that should be monitored include charge magnitude, unit voltage rise time, and pulse repetition rate. The latest edition of IEC 60270-2015 recommends methods for verifying these parameters. However, all of these methods are susceptible to the effects of cable capacitance and the capacitive component of the oscilloscope input impedance, particularly when measuring low charge values. These low charge values are increasingly common in current calibrators. This paper focuses on comparing and analyzing these methods to achieve the lowest possible measurement uncertainty.
Název v anglickém jazyce
Comparative Analysis of Methods for Partial Discharge Calibrator Performance
Popis výsledku anglicky
Partial discharge (PD) calibrators are utilized to determine the conversion constant of a measurement system employed to quantify partial discharge quantities. Since the characteristics of such calibrators may change over time, it is essential to conduct periodic checks on these characteristics at regular intervals and after any repairs. The fundamental parameters that should be monitored include charge magnitude, unit voltage rise time, and pulse repetition rate. The latest edition of IEC 60270-2015 recommends methods for verifying these parameters. However, all of these methods are susceptible to the effects of cable capacitance and the capacitive component of the oscilloscope input impedance, particularly when measuring low charge values. These low charge values are increasingly common in current calibrators. This paper focuses on comparing and analyzing these methods to achieve the lowest possible measurement uncertainty.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2024 IEEE International Conference on High Voltage Engineering and Applications
ISBN
979-8-3503-7499-5
ISSN
2381-5043
e-ISSN
2474-3852
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
Technická universita v Berlíně
Místo vydání
Berlín
Místo konání akce
Berlin
Datum konání akce
18. 8. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
001332851100115