Experimental investigation on the electrostatic receiver with small-sized backing electrode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F14%3A00228727" target="_blank" >RIV/68407700:21260/14:00228727 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.fa2014.agh.edu.pl/fa2014_cd/article/RS/R05A_1.pdf" target="_blank" >http://www.fa2014.agh.edu.pl/fa2014_cd/article/RS/R05A_1.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental investigation on the electrostatic receiver with small-sized backing electrode
Popis výsledku v původním jazyce
A recently published analytical and numerical modeling of an electrostatic transducer with a central cylindrical backing electrode of small radius surrounded by a flat annular cavity behind the circular membrane shows several advantages in terms of sensitivity, bandwidth and the compactness of the device against others designs [J. Acous. Soc. Am. 134(5), 2013, 3573 - 3579]. The experimental study of this kind of transducer is then of interest. For this purpose, an enlarged electrostatic receiver has been fabricated. This device contains the circular membrane of the diameter of 50 mm, the cylindrical backing electrode of the diameter of 20 mm, the thickness of the air gap between them being adjustable. The experimental results, including the membrane displacement field and the pressure sensitivity for different air-gap thicknesses, are presented. The comparison with the results of a previously published theoretical model is discused and possible explanations of the observed discrepancie
Název v anglickém jazyce
Experimental investigation on the electrostatic receiver with small-sized backing electrode
Popis výsledku anglicky
A recently published analytical and numerical modeling of an electrostatic transducer with a central cylindrical backing electrode of small radius surrounded by a flat annular cavity behind the circular membrane shows several advantages in terms of sensitivity, bandwidth and the compactness of the device against others designs [J. Acous. Soc. Am. 134(5), 2013, 3573 - 3579]. The experimental study of this kind of transducer is then of interest. For this purpose, an enlarged electrostatic receiver has been fabricated. This device contains the circular membrane of the diameter of 50 mm, the cylindrical backing electrode of the diameter of 20 mm, the thickness of the air gap between them being adjustable. The experimental results, including the membrane displacement field and the pressure sensitivity for different air-gap thicknesses, are presented. The comparison with the results of a previously published theoretical model is discused and possible explanations of the observed discrepancie
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BI - Akustika a kmity
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/TA02031405" target="_blank" >TA02031405: TRAFFICSENSNET - Senzorické sítě v dopravě</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Forum Acusticum 2014
ISBN
—
ISSN
2221-3767
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Polish Acoustical Society
Místo vydání
Wroclaw
Místo konání akce
Krakow
Datum konání akce
7. 9. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—