Kvalita dentální radiodiagnostiky v České republice - výsledky korespondenčního TLD a filmového auditu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F04%3A04101333" target="_blank" >RIV/68407700:21340/04:04101333 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Quality of Dental Radiography in the Czech Republic - Results of a TLD and Film Postalaudit
Popis výsledku v původním jazyce
Since 2002, the postal audit in dental radiography has been supplementing standard quality control (QC) tools for dental intraoral X-ray machines. An aim of the audit is to check basic X-ray machine parameters (field size, exposure reproducibility), anda quality of the whole process of diagnostic imaging (entrance surface air kerma measurement, a check of film processing, and an image quality evaluation). The standard QC tests, performed by private companies, check mainly the X-ray unit. Over against,the audit gives better information about a practice how patients are examined. During a period of I.2002 - V.2004 about 4000 audits were performed. The results have confirmed well-known fact that the main problems in the dental radiography are connectedwith incorrect film processing, non-optimized setting of the exposure parameters and use of obsolete X-ray machines. Only ~30% of performed audits were satisfactory in all checked parameters.
Název v anglickém jazyce
The Quality of Dental Radiography in the Czech Republic - Results of a TLD and Film Postalaudit
Popis výsledku anglicky
Since 2002, the postal audit in dental radiography has been supplementing standard quality control (QC) tools for dental intraoral X-ray machines. An aim of the audit is to check basic X-ray machine parameters (field size, exposure reproducibility), anda quality of the whole process of diagnostic imaging (entrance surface air kerma measurement, a check of film processing, and an image quality evaluation). The standard QC tests, performed by private companies, check mainly the X-ray unit. Over against,the audit gives better information about a practice how patients are examined. During a period of I.2002 - V.2004 about 4000 audits were performed. The results have confirmed well-known fact that the main problems in the dental radiography are connectedwith incorrect film processing, non-optimized setting of the exposure parameters and use of obsolete X-ray machines. Only ~30% of performed audits were satisfactory in all checked parameters.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník rozšířených abstraktů XXVI. Dny radiační ochrany
ISBN
80-01-03076-8
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
223-226
Název nakladatele
ČVUT, Fakulta jaderná a fyzikálně inženýrská, KDAIZ
Místo vydání
Praha
Místo konání akce
Luhačovice
Datum konání akce
1. 11. 2004
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—