Vývoj radiační ochrany v zubní intraorální radiodiagnostice v letech 2002 až 2005 - analýza výsledků korespondenčního auditu
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F05%3A04117047" target="_blank" >RIV/68407700:21340/05:04117047 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of Radiation Protection in Intraoral Dental Radiography During the Years 2002-2005 - Analysis of Postal Audit Results
Popis výsledku v původním jazyce
Since 2002, the postal audit in dental radiography has been supplementing standard quality control (QC) tools for dental intraoral X-ray machines. An aim of the audit is to check basic X-ray machine parameters (field size, exposure reproducibility), anda quality of the whole process of diagnostic imaging (incident air kerma measurement, a check of film processing, and an image quality evaluation). During the years 2002 - 2005 more than 5000 audits were performed. The results have confirmed well-known fact that the main problems in the dental radiography are connected with incorrect film processing and non-optimized setting of the exposure parameters. However, the situation is coming better at present. About 50 % of performed audits were satisfactory in all checked parameters over against 19 % in the year 2002. The results of incident air kerma measurements have shown that a new diagnostic reference level should be set to 3 mGy for intraoral examination with a dental film.
Název v anglickém jazyce
Development of Radiation Protection in Intraoral Dental Radiography During the Years 2002-2005 - Analysis of Postal Audit Results
Popis výsledku anglicky
Since 2002, the postal audit in dental radiography has been supplementing standard quality control (QC) tools for dental intraoral X-ray machines. An aim of the audit is to check basic X-ray machine parameters (field size, exposure reproducibility), anda quality of the whole process of diagnostic imaging (incident air kerma measurement, a check of film processing, and an image quality evaluation). During the years 2002 - 2005 more than 5000 audits were performed. The results have confirmed well-known fact that the main problems in the dental radiography are connected with incorrect film processing and non-optimized setting of the exposure parameters. However, the situation is coming better at present. About 50 % of performed audits were satisfactory in all checked parameters over against 19 % in the year 2002. The results of incident air kerma measurements have shown that a new diagnostic reference level should be set to 3 mGy for intraoral examination with a dental film.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD202%2F05%2FH031" target="_blank" >GD202/05/H031: Využití ionizujícího záření v dozimetrii a radiologické fyzice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Conference Proceedings - XXVII. Days of Radiation Protection
ISBN
80-88806-53-4
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
1-2
Název nakladatele
Society of Nuclear Medicine and Radiation Hygiene of Slovak Medical Association
Místo vydání
Bratislava
Místo konání akce
Liptovský Ján
Datum konání akce
28. 11. 2005
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—