Zhodnocení metody optimalizace radioaktivity aplikované pacientům s nízkou hmotností pro SPECT a PET zobrazovaní
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F06%3A04124405" target="_blank" >RIV/68407700:21340/06:04124405 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Evaluation of Weight-Optimized Radioactivity Administration for PET and SPECT Imaging of Pediatric Patients
Popis výsledku v původním jazyce
Nowadays, almost every nuclear medicine department uses the EANM (European Association of Nuclear Medicine) pediatric task group recommendation. The task group suggested that activity given to patients should be calculated as a weight-dependent fractionof the activity in reference patient, irrespective of applied tracer. These correction factors are commonly used for gamma scintigraphy systems (SPECT) along with positron emission tomography (PET) and do not consider physical properties of PET and SPECTimaging, e.g. different photon energies, length and weight ratio of patient or sensitivity of imaging systems etc. Aim of this study was to evaluate the influence of these aspects on image quality of PET and SPECT imaging.
Název v anglickém jazyce
Evaluation of Weight-Optimized Radioactivity Administration for PET and SPECT Imaging of Pediatric Patients
Popis výsledku anglicky
Nowadays, almost every nuclear medicine department uses the EANM (European Association of Nuclear Medicine) pediatric task group recommendation. The task group suggested that activity given to patients should be calculated as a weight-dependent fractionof the activity in reference patient, irrespective of applied tracer. These correction factors are commonly used for gamma scintigraphy systems (SPECT) along with positron emission tomography (PET) and do not consider physical properties of PET and SPECTimaging, e.g. different photon energies, length and weight ratio of patient or sensitivity of imaging systems etc. Aim of this study was to evaluate the influence of these aspects on image quality of PET and SPECT imaging.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2006
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IFMBE Proceedings World Congress on Medical Physics and Biomedical Engineering 2006
ISBN
3-540-36839-6
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
244-245
Název nakladatele
Springer-Verlag
Místo vydání
Berlin
Místo konání akce
Seoul
Datum konání akce
27. 8. 2006
Typ akce podle státní příslušnosti
WRD - Celosvětová akce