Stanovení efektivních dávek pro pracovníky jeskyní: experimenty s pasivními detektory
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F08%3A04150075" target="_blank" >RIV/68407700:21340/08:04150075 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors
Popis výsledku v původním jazyce
The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN consists of a plastic chamber that is conical cylindrical in shape and about 0,5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited RnDP. Kodak has a spectrometric character - the tracks are visualized only for alphas with energies between 1 MeV and 3 MeV that touch the foil; thus the effective volume has a lens shape. The response therefore corresponds to diffused radon and half of 218Po born by radon gas decay. The experiments described below were conducted as one part of a routine methodology control, focused on classifying worker irradiationfrom natural ionizing radiation sources in show caves and in caves used for speleotherapy.
Název v anglickém jazyce
Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors
Popis výsledku anglicky
The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN consists of a plastic chamber that is conical cylindrical in shape and about 0,5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited RnDP. Kodak has a spectrometric character - the tracks are visualized only for alphas with energies between 1 MeV and 3 MeV that touch the foil; thus the effective volume has a lens shape. The response therefore corresponds to diffused radon and half of 218Po born by radon gas decay. The experiments described below were conducted as one part of a routine methodology control, focused on classifying worker irradiationfrom natural ionizing radiation sources in show caves and in caves used for speleotherapy.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/JC_12%2F2006" target="_blank" >JC_12/2006: Zkvalitnění osobní dozimetrie pracovníků ve veřejnosti přístupných jeskyních a v jeskyních využívaných pro speleoterapii s možností rozšíření na ostatní podzemní pracoviště</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Svazek periodika
130
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
000259206500012
EID výsledku v databázi Scopus
—