Odhad efektivní dávky pro pracovníky jeskyní České republiky: esperimenty s pasivními detektory
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F70565813%3A_____%2F08%3A%230000175" target="_blank" >RIV/70565813:_____/08:#0000175 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effective dose assessment for works in caves in the Czech Republic: experiments with passive radon detectors
Popis výsledku v původním jazyce
The new RAMARN system for radon volume activity measurement was developed in 2003 and has been used since this year.RAMARN system consists of a plastic chamber of conical form with 0,5 l of capacity and detector Kodak LR 115 that is located on f this diffusion chamber.The sice was chosen to avoid the influence of deposited decay products of radon. Kodak has a spektrometric character - the traks are visualized only for Alpha particles with energies between 1 and 3 MeV, that touch the foil.This the effective volume has a lens shape. The responce therefore sorresponds to diffused radon and half of 218 Po born by radon gas decay. The experiments were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleology.
Název v anglickém jazyce
Effective dose assessment for works in caves in the Czech Republic: experiments with passive radon detectors
Popis výsledku anglicky
The new RAMARN system for radon volume activity measurement was developed in 2003 and has been used since this year.RAMARN system consists of a plastic chamber of conical form with 0,5 l of capacity and detector Kodak LR 115 that is located on f this diffusion chamber.The sice was chosen to avoid the influence of deposited decay products of radon. Kodak has a spektrometric character - the traks are visualized only for Alpha particles with energies between 1 and 3 MeV, that touch the foil.This the effective volume has a lens shape. The responce therefore sorresponds to diffused radon and half of 218 Po born by radon gas decay. The experiments were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleology.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
DN - Vliv životního prostředí na zdraví
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Svazek periodika
130
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—