Calculation of responses and analysis of experimental data for silicon gamma spectrometer
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F10%3A00166522" target="_blank" >RIV/68407700:21340/10:00166522 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calculation of responses and analysis of experimental data for silicon gamma spectrometer
Popis výsledku v původním jazyce
Silicon detector for spectrometry gamma was tested for photon energy interval up to 10 MeV. Relatively low sensitivity and radiation tolerance for neutrons makes this system perspective for gamma spectrometry in the mixed neutron gamma fields. Responsesof this spectrometry system were simulated using Monte Carlo method (MCNPX code). Results were compared with the corresponding experimental data (isotopic radiation sources 137Cs, 60Co, 22Na and gamma line 4.43 MeV from Am-Be source). Using the best fitthe set of energy deposition spectra for given detection system, two experimental arrangements (beam parallel and perpendicular to detector axis) and energy interval from 20 keV up to 10 MeV were calculated. Model responses of detection system were simulated using convolution of energy deposition spectra with detection system resolution function. Detection system response matrix was constructed from simulated responses. Different methods of data processing and unfolding were tested.
Název v anglickém jazyce
Calculation of responses and analysis of experimental data for silicon gamma spectrometer
Popis výsledku anglicky
Silicon detector for spectrometry gamma was tested for photon energy interval up to 10 MeV. Relatively low sensitivity and radiation tolerance for neutrons makes this system perspective for gamma spectrometry in the mixed neutron gamma fields. Responsesof this spectrometry system were simulated using Monte Carlo method (MCNPX code). Results were compared with the corresponding experimental data (isotopic radiation sources 137Cs, 60Co, 22Na and gamma line 4.43 MeV from Am-Be source). Using the best fitthe set of energy deposition spectra for given detection system, two experimental arrangements (beam parallel and perpendicular to detector axis) and energy interval from 20 keV up to 10 MeV were calculated. Model responses of detection system were simulated using convolution of energy deposition spectra with detection system resolution function. Detection system response matrix was constructed from simulated responses. Different methods of data processing and unfolding were tested.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
ISSN
0168-9002
e-ISSN
—
Svazek periodika
619
Číslo periodika v rámci svazku
1-3
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
4
Strana od-do
—
Kód UT WoS článku
000280026300048
EID výsledku v databázi Scopus
—