Segmentation of MRI data by means of nonlinear diffusion
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F13%3A00210905" target="_blank" >RIV/68407700:21340/13:00210905 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00023001:_____/13:00058781
Výsledek na webu
<a href="http://www.kybernetika.cz/content/2013/2/301/paper.pdf" target="_blank" >http://www.kybernetika.cz/content/2013/2/301/paper.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Segmentation of MRI data by means of nonlinear diffusion
Popis výsledku v původním jazyce
The article focuses on the application of the segmentation algorithm based on the numerical solution of the Allen-Cahn non-linear diffusion partial differential equation. This equation is related to the motion of curves by mean curvature. It exhibits several suitable mathematical properties including stable solution profile. This allows the user to follow accurately the position of the segmentation curve by bringing it quickly to the vicinity of the segmented object and by approaching the details of thesegmentation curve. The purpose of the article is to indicate how the algorithm parameters are set up and to show how the algorithm behaves when applied to the particular class of medical data. In detail we describe the algorithm parameters influencingthe segmentation procedure. The left ventricle volume estimated by the segmentation of scanned slices is evaluated through the cardiac cycle. Consequently, the ejection fraction is evaluated. The described approach allows the user to proc
Název v anglickém jazyce
Segmentation of MRI data by means of nonlinear diffusion
Popis výsledku anglicky
The article focuses on the application of the segmentation algorithm based on the numerical solution of the Allen-Cahn non-linear diffusion partial differential equation. This equation is related to the motion of curves by mean curvature. It exhibits several suitable mathematical properties including stable solution profile. This allows the user to follow accurately the position of the segmentation curve by bringing it quickly to the vicinity of the segmented object and by approaching the details of thesegmentation curve. The purpose of the article is to indicate how the algorithm parameters are set up and to show how the algorithm behaves when applied to the particular class of medical data. In detail we describe the algorithm parameters influencingthe segmentation procedure. The left ventricle volume estimated by the segmentation of scanned slices is evaluated through the cardiac cycle. Consequently, the ejection fraction is evaluated. The described approach allows the user to proc
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BA - Obecná matematika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Kybernetika
ISSN
0023-5954
e-ISSN
—
Svazek periodika
49
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
18
Strana od-do
301-318
Kód UT WoS článku
000329259300007
EID výsledku v databázi Scopus
—