DETERMINING RADIOACTIVE AEROSOL CONCENTRATIONS USING A SURFACE RADIOACTIVE CONTAMINATION MEASUREMENT DEVICE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F15%3A00235742" target="_blank" >RIV/68407700:21340/15:00235742 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/70565813:_____/15:#0000440 RIV/68407700:21340/15:00232423
Výsledek na webu
<a href="http://dx.doi.org/10.1093/rpd/ncv338" target="_blank" >http://dx.doi.org/10.1093/rpd/ncv338</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/rpd/ncv338" target="_blank" >10.1093/rpd/ncv338</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
DETERMINING RADIOACTIVE AEROSOL CONCENTRATIONS USING A SURFACE RADIOACTIVE CONTAMINATION MEASUREMENT DEVICE
Popis výsledku v původním jazyce
For our experiments in the aerosol chamber, it is desirable to know the activity of radioactive aerosols applied to the chamber. For this purpose was purchased a COLIBRI TTC survey meter with a SABG-15+ probe (Canberra, USA), which is designed for measuring surface contamination. This probe is used to measure activity of aerosols deposited on the filters during the experiments in the aerosol chamber. Since the probe is calibrated in different geometry, the probe response in our experimental geometry wassimulated by Monte Carlo method. The Monte Carlo model of the probe using the MCNPX and experimental verification of this model are presented. Consequently the initial results of experimental measurement in our aerosol chamber are presented.
Název v anglickém jazyce
DETERMINING RADIOACTIVE AEROSOL CONCENTRATIONS USING A SURFACE RADIOACTIVE CONTAMINATION MEASUREMENT DEVICE
Popis výsledku anglicky
For our experiments in the aerosol chamber, it is desirable to know the activity of radioactive aerosols applied to the chamber. For this purpose was purchased a COLIBRI TTC survey meter with a SABG-15+ probe (Canberra, USA), which is designed for measuring surface contamination. This probe is used to measure activity of aerosols deposited on the filters during the experiments in the aerosol chamber. Since the probe is calibrated in different geometry, the probe response in our experimental geometry wassimulated by Monte Carlo method. The Monte Carlo model of the probe using the MCNPX and experimental verification of this model are presented. Consequently the initial results of experimental measurement in our aerosol chamber are presented.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/VF20112015013" target="_blank" >VF20112015013: Výzkum moderních metod detekce a identifikace nebezpečných CBRN látek a materiálů, metod snížení jejich nebezpečnosti a dekontaminace; výzkum moderních prostředků ochrany osob a prvků kritické infrastruktury</a><br>
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiation Protection Dosimetry
ISSN
0144-8420
e-ISSN
—
Svazek periodika
164
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
4
Strana od-do
533-536
Kód UT WoS článku
000356726000015
EID výsledku v databázi Scopus
2-s2.0-84942134013