Calculation of cellular S-values using Geant4-DNA: The effect of cell geometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F15%3A00236108" target="_blank" >RIV/68407700:21340/15:00236108 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.apradiso.2015.06.027" target="_blank" >http://dx.doi.org/10.1016/j.apradiso.2015.06.027</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.apradiso.2015.06.027" target="_blank" >10.1016/j.apradiso.2015.06.027</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Calculation of cellular S-values using Geant4-DNA: The effect of cell geometry
Popis výsledku v původním jazyce
Calculations of cellular S-values for monoenergetic electron sources with energy from 1 to 100 keV and the Auger-electron emitting radionuclides Tc-99m, In-111, and I-125 have been made using the Geant4 Monte Carlo toolkit. The Geant4-DNA low-energy extension is employed for simulating collision-by-collision the complete slowing-down of electron tracks (down to 8 eV) in liquid water, used as a surrogate of human cells. The effect of cell geometry on S-values is examined by simulating electron tracks within different cell geometries, namely, a spherical, two ellipsoidal, and an irregular shape, all having equal cellular and nuclear volumes. Algorithms for randomly sampling the volume of the nucleus, cytoplasm, surface, and whole cell for each cell phantom are presented.
Název v anglickém jazyce
Calculation of cellular S-values using Geant4-DNA: The effect of cell geometry
Popis výsledku anglicky
Calculations of cellular S-values for monoenergetic electron sources with energy from 1 to 100 keV and the Auger-electron emitting radionuclides Tc-99m, In-111, and I-125 have been made using the Geant4 Monte Carlo toolkit. The Geant4-DNA low-energy extension is employed for simulating collision-by-collision the complete slowing-down of electron tracks (down to 8 eV) in liquid water, used as a surrogate of human cells. The effect of cell geometry on S-values is examined by simulating electron tracks within different cell geometries, namely, a spherical, two ellipsoidal, and an irregular shape, all having equal cellular and nuclear volumes. Algorithms for randomly sampling the volume of the nucleus, cytoplasm, surface, and whole cell for each cell phantom are presented.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BG - Jaderná, atomová a molekulová fyzika, urychlovače
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
—
Svazek periodika
104
Číslo periodika v rámci svazku
—
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
11
Strana od-do
113-123
Kód UT WoS článku
000360948600016
EID výsledku v databázi Scopus
2-s2.0-84935464173