3D Dosimetry based on a new optical approach for dosimetry gels: Use of the polarisation ratio of the scattering light
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F17%3A00312245" target="_blank" >RIV/68407700:21340/17:00312245 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1088/1742-6596/847/1/012010" target="_blank" >https://doi.org/10.1088/1742-6596/847/1/012010</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1742-6596/847/1/012010" target="_blank" >10.1088/1742-6596/847/1/012010</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
3D Dosimetry based on a new optical approach for dosimetry gels: Use of the polarisation ratio of the scattering light
Popis výsledku v původním jazyce
Several investigations have been carried out by researchers over past two decades to evaluate and perform the reading of gel dosimeters for the three-dimensional measurement of radiation fields. Imaging of the gels has been successfully accomplished with clinical MRI and via laser-based optical scanning using transmission of the light. We report here the methodology and results of a preliminary study carried out to evaluate the utility of a new and simplified approach to make 3D imaging of gel radiation dosimeters based on the scattering light analysis. For the purpose of this initial investigation, nMAG gel has been studied by our method. All pictures were evaluated through a region-of-interest (ROI) analysis to obtain the average change in image density in each sample as a function of the radiation dose. These measured ROI values were subjected to any fit and given a calibration dose and a spatial resolution. This way, we performed a 3D reconstruction of a dosimeter gel.
Název v anglickém jazyce
3D Dosimetry based on a new optical approach for dosimetry gels: Use of the polarisation ratio of the scattering light
Popis výsledku anglicky
Several investigations have been carried out by researchers over past two decades to evaluate and perform the reading of gel dosimeters for the three-dimensional measurement of radiation fields. Imaging of the gels has been successfully accomplished with clinical MRI and via laser-based optical scanning using transmission of the light. We report here the methodology and results of a preliminary study carried out to evaluate the utility of a new and simplified approach to make 3D imaging of gel radiation dosimeters based on the scattering light analysis. For the purpose of this initial investigation, nMAG gel has been studied by our method. All pictures were evaluated through a region-of-interest (ROI) analysis to obtain the average change in image density in each sample as a function of the radiation dose. These measured ROI values were subjected to any fit and given a calibration dose and a spatial resolution. This way, we performed a 3D reconstruction of a dosimeter gel.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IC3DDOse Programme 2016
ISBN
—
ISSN
1742-6596
e-ISSN
1742-6596
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
The University of Texas
Místo vydání
Arlington
Místo konání akce
Galveston, Texas
Datum konání akce
7. 11. 2016
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000437884300010