Study of the parameters of the pulse shape method and experimental test of diamond based detector at the VR-1 reactor
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21340%2F20%3A00337368" target="_blank" >RIV/68407700:21340/20:00337368 - isvavai.cz</a>
Výsledek na webu
<a href="https://doi.org/10.1016/j.anucene.2020.107431" target="_blank" >https://doi.org/10.1016/j.anucene.2020.107431</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.anucene.2020.107431" target="_blank" >10.1016/j.anucene.2020.107431</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Study of the parameters of the pulse shape method and experimental test of diamond based detector at the VR-1 reactor
Popis výsledku v původním jazyce
Diamond crystal-based detector for neutron flux measurement is a promising solution as a fast, small and stable detector especially suited for fast transient measurements. The work aims to test the method and to find the best parameters of the pulse shape analysis for the thermal neutron detection. The developed diamond detectors were tested with the AmBe neutron source and in the VR-1 reactor core. Based on the results obtained from the AmBe measurements, the discrimination conditions for the pulse shape analysis were set and optimized. The diamond detector was then tested in mixed n- field of the nuclear reactor core. First results from the VR-1 reactor measurement showed high yield of thermal neutron interactions (up to 33% of all recorded interactions, like in AmBe measurements). The presented results therefore proved that diamond detectors are promising for the fast transient measurements.
Název v anglickém jazyce
Study of the parameters of the pulse shape method and experimental test of diamond based detector at the VR-1 reactor
Popis výsledku anglicky
Diamond crystal-based detector for neutron flux measurement is a promising solution as a fast, small and stable detector especially suited for fast transient measurements. The work aims to test the method and to find the best parameters of the pulse shape analysis for the thermal neutron detection. The developed diamond detectors were tested with the AmBe neutron source and in the VR-1 reactor core. Based on the results obtained from the AmBe measurements, the discrimination conditions for the pulse shape analysis were set and optimized. The diamond detector was then tested in mixed n- field of the nuclear reactor core. First results from the VR-1 reactor measurement showed high yield of thermal neutron interactions (up to 33% of all recorded interactions, like in AmBe measurements). The presented results therefore proved that diamond detectors are promising for the fast transient measurements.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Annals of Nuclear Energy
ISSN
0306-4549
e-ISSN
—
Svazek periodika
142
Číslo periodika v rámci svazku
July
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
—
Kód UT WoS článku
000526111700047
EID výsledku v databázi Scopus
2-s2.0-85081001675