Popis výsledku v původním jazyce
The neutron spectrum was measured at two locations in the spent fuel storage facility of the Temelín nuclear power plant. The measurement had two primary objectives: to map the neutron -γ field by quantifying the ambient dose equivalent H*(10) and to identify methods that could improve the quality of the adjusted neutron spectrum using a Bonner Sphere Spectrometer (BSS). Three spectrometers were used: a BSS and two proton recoil spectrometers. Hydrogen-filled proportional counters and an EJ309 scintillator were used to construct the a priori spectrum for BSS adjustment. The details of this process and its results are discussed. The a posteriori spectrum was used to calculate the ambient dose equivalent H*(10). The resulting spectrum is highly thermalised, but the predominant contribution to H*(10) was in the 100 keV-1.3 MeV range. The use of hydrogen-proportional counters in combination with the BSS is recommended.
Název v anglickém jazyce
Measurement of neutron spectra in spent fuel storage
Popis výsledku anglicky
The neutron spectrum was measured at two locations in the spent fuel storage facility of the Temelín nuclear power plant. The measurement had two primary objectives: to map the neutron -γ field by quantifying the ambient dose equivalent H*(10) and to identify methods that could improve the quality of the adjusted neutron spectrum using a Bonner Sphere Spectrometer (BSS). Three spectrometers were used: a BSS and two proton recoil spectrometers. Hydrogen-filled proportional counters and an EJ309 scintillator were used to construct the a priori spectrum for BSS adjustment. The details of this process and its results are discussed. The a posteriori spectrum was used to calculate the ambient dose equivalent H*(10). The resulting spectrum is highly thermalised, but the predominant contribution to H*(10) was in the 100 keV-1.3 MeV range. The use of hydrogen-proportional counters in combination with the BSS is recommended.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10304 - Nuclear physics
Návaznosti výsledku
Projekt
<a href="/cs/project/TK04010108" target="_blank" >TK04010108: Metodika měření spekter neutronů a gama záření ve směsných polích zejména pro osobní dozimetrii</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Radiation and Isotopes
ISSN
0969-8043
e-ISSN
1872-9800
Svazek periodika
214
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
—
Kód UT WoS článku
001339713000001
EID výsledku v databázi Scopus
2-s2.0-85206684508